Electromagnetic compatibility (EMC) Part 2-8: Environment Voltage dips and short interruptions on public electric power supply systems with statistical measurement results

$186.00 $371.99 -50%
Product Code: IEC TR 61000-2-8
Stock In Stock
Edition: 1.0
Published: 11/2002
Number of Pages: 98
File Size: 1 file, 1 Byte

Available Options

Product Description

Electromagnetic compatibility (EMC) Part 2-8: Environment Voltage dips and short interruptions on public electric power supply systems with statistical measurement results

Introduction: IEC 61000 is published in separate parts according to the following structure: Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (in so far as they do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part is further subdivided into several parts, published either as International Standards, technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and completed by a second number identifying the subdivision (example: 61000-6-1). Detailed information on the various types of disturbances that can be expected on public power supply systems can be found in IEC 61000-2-1.

Scope: This technical report describes the electromagnetic disturbance phenomena of voltage dips and short interruptions in terms of their sources, effects, remedial measures, methods of measurement, and measurement results (in so far as these are available). They are discussed primarily as phenomena observed on the networks of public electricity supply systems and having an effect on electrical equipment receiving its energy supply from those systems. “Voltage sag” is an alternative name for the phenomenon voltage dip. Definitions 2.1 voltage dip voltage sag sudden reduction of the voltage at a particular point on an electricity supply system below a specified dip threshold followed by its recovery after a brief interval NOTE 1 Typically a dip is associated with the occurrence and termination of a short circuit or other extreme current increase on the system or installations connected to it. NOTE 2 A voltage dip is a two-dimensional electromagnetic disturbance, the level of which is determined by both voltage and time (duration). 2.2 short interruption sudden reduction of the voltage on all phases at a particular point on an electricity supply system below a specified interruption threshold followed by its restoration after a brief interval NOTE Short interruptions are typically associated with switchgear operation related to the occurrence and termination of short circuits on the system or installations connected to it. 2.3 (voltage dip) reference voltage value specified as the base on which depth, thresholds and other values are expressed in per unit or percentage terms NOTE The nominal or declared voltage of the supply system is frequently selected as the reference voltage. 2.4 voltage dip start threshold r.m.s. value of the voltage on an electricity supply system specified for the purpose of defining the start of a voltage dip NOTE Typically values between 0,85 and 0,95 of the reference voltage have been used for this threshold.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 61000-2-8-2002 PDF

IEC TR 61000-2-8-2002 PDF

$186.00 $371.99