Electromagnetic compatibility (EMC) – Part 4-37: Testing and measurement techniques – Calibration and verification protocol for harmonic emission compliance test systems
Introduction: Harmonic current analysis systems are used to measure emissions from equipment that is tested in accordance with various standards. The IEC (International Electrotechnical Commission) adopted measurement and evaluation techniques that are specified in IEC 61000-4-7, but limits, limit comparisons, certain exclusions, and test conditions for a variety of products are specified in IEC 61000-3-2 (for 16 A per phase and below) and IEC 61000–3-12 (from 16 A to 75 A per phase). This Technical Report provides test patterns for IEC 61000-3-2, but will be expanded in future editions to also include specific tests per IEC 61000-3-12 for currents above 16 A per phase. The methodology described in this Technical Report can also be expanded to provide fluctuating harmonics, along with inter- harmonics. This Technical Report is neither intended as a type test nor as an exhaustive test of all required analyzer capabilities according to IEC 61000-3-2, IEC 61000-3-12, and IEC 61000-4-7. The primary objective is to verify on a periodic basis (for example for renewal of accreditation) that the harmonic analysis test system, consisting of a previously type tested analyzer and a suitable power source, performs correctly, and the performance of the system is not adversely affected by the system integration, nor has changed over a period of time. The purpose of the harmonic current analysis systems is to evaluate harmonic current emissions, the power factor, and other parameters, in accordance with
Scope: This part of IEC 61000, which is a Technical Report, outlines a typical test procedure for harmonic analysis in systems comprising tests apparatus designed to comply with IEC 61000-4-7, and products designed to comply with IEC 61000-3-2 and/or IEC 61000-3-12. The test procedure is intended to provide a systematic guidance suitable for use by manufacturers, end users, independent test laboratories and other bodies, for the purpose of determining the applicable compliance status within a wide range of harmonic current emissions. The test procedure is derived from conditions observed in actual product testing and simulates closely conditions that can reasonably be expected. The accuracy of harmonic analyzers and complete tests systems having adjustments or procedures, either hardware or software-based, may be optimized using external reference equipment of sufficient accuracy and the methodology in this Technical Report. This Technical Report is not intended as a replacement for type testing of harmonic analyzers, nor does it check all of the parameters specified in IEC 61000-4-7, IEC 61000-3-2, and IEC 61000-3-12.
Contents:
- FOREWORD
- INTRODUCTION
- Scope