IEC TR 61341-2010 PDF

IEC TR 61341-2010 PDF

Method of measurement of centre beam intensity and beam angle(s) of reflector lamps

$25.22 $50.44 -50%
Product Code: IEC TR 61341
Stock In Stock
Edition: 2.0
Published: 02/2010
Number of Pages: 24
File Size: 1 file, 901 Bytes

Available Options

Product Description

Method of measurement of centre beam intensity and beam angle(s) of reflector lamps

Introduction: While the light output of lamps is normally characterized by the luminous flux, for reflector lamps it is characterized by the centre beam intensity together with the beam angle(s). This Technical Report gives guidance with regard to the measurement and interpretation of these two basic characteristics of reflector lamps in order to allow the comparability of reported values. The adopted principles may help to classify lamps into beam angle groups; they are not intended for the assessment of individual lamps. For additional information, the reader is referred to the CIE Technical Report No 43, describing the photometric characteristics of floodlight luminaires.

Scope: This Technical Report describes the method of measuring and specifying the centre beam intensity and the associated beam angle(s) of reflector lamps. It applies to incandescent, tungsten halogen and gas-discharge and LED based reflector lamps for general lighting purposes. It does not apply to lamps for special purposes such as projection lamps. These recommendations relate to design testing of lamps only. Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 optical beam axis the axis about which the luminous intensity distribution is substantially symmetrical NOTE 1 The optical beam axis is not necessarily the same as the lamp axis through the lamp cap or the lamp axis normal to a reference plane on the reflector (e.g. the rim), see Figure 1. NOTE 2 It is assumed that only small (negligible) errors occur when symmetry is determined visually. Figure 1 – Relation between optical beam axis, geometrical-mechanical axis, peak intensity and centre beam intensity 2.2 peak intensity Ip the highest value of the luminous intensity regardless of whether or not it occurs on the optical beam axis NOTE The peak intensity is expressed in candela. 2.3 centre beam intensity the value of the luminous intensity measured on the optical beam axis NOTE The centre beam intensity is expressed in candela. Optical beam axis Mechanical/geometrical axis Center beam intensity Peak intensity IEC 292/10 – 12 – TR 61341 © CEI:2010 AVANT-PROPOS..................................................................................................................13 INTRODUCTION...................................................................................................................15 Domaine d'application ....................................................................................................16 Termes et définitions ......................................................................................................16 Formes de base des faisceaux .......................................................................................17 Conditions générales de mesures................................................................

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 61341-2010 PDF

IEC TR 61341-2010 PDF

$25.22 $50.44