Communication networks and systems for power utility automation – Part 7-6: Guideline for definition of Basic Application Profiles (BAPs) using IEC 61850
Introduction: The IEC 61850 series of standards offers a broad basis for communication networks and systems in power utility automation. Due to its broad coverage of power utility automation applications, it is up to the standard's user (utility, vendor, system integrator, etc.) to pick and choose specific options from the standard in order to meet the requirements of the intended objective. As a consequence, implementations of IEC 61850 represent specific subsets of the standard. In the context of standards, the term "profile" is commonly used to describe a subset of an entity (e.g. standard, model, rules). Accordingly, an IEC 61850 standard profile contains a selection of data models (mandatory elements), applicable communication services and relevant engineering conventions (based on the Substation Configuration Language SCL defined in IEC 61850-6) for an application function of a specific use case in the domain of power utility automation. Depending on the scope and objective different profile types can be distinguished: User profile – defined subset that is valid for a specific user / organization (e.g. utility) Product / device profile – implemented subset in a specific vendor product / device Domain profile – defined subset for a specific domain and relevant use cases (e.g. monitoring of substation) Application / function profile – subset covering a specific application or function (e.g. substation interlocking) These profile types target the reduction of complexity and facilitation
Scope: 1.1 General This part of IEC 61850, which is a Technical Report, is focused on building application / function profiles and specifies a methodology to define Basic Application Profiles (BAPs), in textual documents (edition 1, 2019) or in a machine processable SCL format (current edition). These Basic Application Profiles provide a framework for interoperable interaction within or between typical substation automation functions. BAPs are intended to define a subset of features of IEC 61850 in order to facilitate interoperability in a modular way in practical applications. It is the intention of this document to provide a common and generic way to describe the functional behavior of a specific application function in the domain of power utility automation systems as a common denominator of various possible interpretations/implementations of using IEC 61850. The guidelines in this document are based on the functional definitions of: IEC 61850-5, Communication requirements for functions and device models, which gives a comprehensive overview of all application functions needed in a state-of-the-art substation automation implementation. IEC TR 61850-7-500, Basic information and communication structure – Use of logical nodes for modelling application functions and related concepts and guidelines for substations, which illustrates and explains application functions for the substation/protection domain of Logical Nodes in modelling simple and complex functions, to improve common understanding in modelling and data exchange, and finally to lead to interoperable implementations. IEC TR 61850-90-3, Using IEC 61850 for condition monitoring diagnosis and analysis, which gives use cases and data modelling for condition monitoring diagnosis and analysis functions for substation and power grid facilities. IEC TR 61850-90-30, IEC 61850 Function Modelling in SCL, which describes extensions of the SCL Substation/Process Section allowing to create a comprehensive, IED and hardware independent specification of an IEC 61850 based power system. This document does not describe the applications and respective implementation requirements; the focus is on their typical information exchang
Contents:
- FOREWORD
- INTRODUCTION
- Scope