IEC TR 61850-90-20-2025 PDF

IEC TR 61850-90-20-2025 PDF

Communication networks and systems for power utility automation - Part 90-20: Use cases of redundancy in systems

$163.93 $327.86 -50%
Product Code: IEC TR 61850-90-20
Stock In Stock
Edition: 1.0
Published: 08/2025
Number of Pages: 36
File Size: 1 file, 680 Bytes

Available Options

Product Description

Communication networks and systems for power utility automation - Part 90-20: Use cases of redundancy in systems

Introduction: Parts of this document are based on IEC TR 61850-90-2, Communication networks and systems for power utility automation – Part 90-2: Using IEC 61850 for communication between substations and control centres. Redundancy is used to increase the availability of a system. This document describes different types of redundancy (denoted as redundancy schemes), while focusing on device redundancy. Put into simple words, device redundancy is using two physically different devices for the same purpose. If one of them fails, the other one takes over. The failover time of the affected components, which results in a downtime of this part of the system, is as little as possible. In this way, continuous operation is ensured. Loss of data can be avoided. Since redundant devices provide equal functionality at the same time, information flow to and from these devices is often duplicated. Therefore, components of a redundant system are able to handle duplicated data. Figure 1 and Figure 2 describe two basic redundancies. The first one shows redundant clients, the second one shows redundant servers. Blue lines indicate dataflow, the green dotted lines indicate an option for shared data between the two redundant components. In the first example a server in IED A has two redundant clients, one in each of IED G and H. In the second example, a client in IED H has two redundant servers, IED A and IED B. Figure 1 – Basic redundancy scheme, Redundant Client Figure 2 – Basic redundancy scheme, Redundant

Scope: This part of IEC 61850, which is a technical report, describes use cases of redundancy in systems. This document considers use cases of duplication of function and devices and covers redundancy of information flow at message level. Functional safety is out of scope of this document. To keep focus on details relevant for this document, some figures and drawings do not show electrical wiring, redundant coils, etc, where this is not important for the use case. This document is not a guideline on the design of redundancy systems; guidance on designing redundancy systems can be found in textbooks such as [1]1 and [2].

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 61850-90-20-2025 PDF

IEC TR 61850-90-20-2025 PDF

$163.93 $327.86