High-voltage direct current (HVDC) systems – Guidance to the specification and design evaluation of AC filters – Part 1: Overview
Introduction: The IEC TR 62001 series is structured in four five parts: IEC TR 62001-1 – Overview This part concerns specifications of AC filters for high-voltage direct current (HVDC) systems with line-commutated converters, permissible distortion limits, harmonic generation, filter arrangements, filter performance calculation, filter switching and reactive power management and customer specified parameters and requirements. IEC TR 62001-2 – Performance This part deals with current-based interference criteria, design issues and special applications, field measurements and verification. IEC TR 62001-3 – Modelling This part addresses the harmonic interaction across converters, pre-existing harmonics, AC network impedance modelling, simulation of AC filter performance. IEC TR 62001-4 – Equipment This part concerns steady-state and transient ratings of AC filters and their components, power losses, audible noise, design issues and special applications, filter protection, seismic requirements, equipment design and test parameters. IEC TR 62001-51 – AC side harmonics and appropriate harmonic limits for high-voltage direct current (HVDC) systems with voltage sourced converters (VSC) This document concerns specific issues of AC filter design related to VSC HVDC systems. Parts 1 to 4 are written with focus on line commutated converters. ____________ 1 Under preparation. Stage at the time of publication: IEC/RPUB 62001-5:2021.
Scope: This part of IEC 62001, which is a Technical Report, deals with the specification and design evaluation of AC side harmonic performance and AC side filters for HVDC schemes. It is intended to be primarily for the use of the utilities and consultants who are responsible for issuing the specifications for new HVDC projects and evaluating designs proposed by prospective suppliers. This document provides guidance on the specifications of AC filters for high-voltage direct current (HVDC) systems with line-commutated converters and filter performance calculation. The scope of this document covers AC side filtering for the frequency range of interest in terms of harmonic distortion and audible frequency disturbances. Where the term "HVDC converter" or "HVDC station" is referred to without qualification, in this document, it is understood to refer to LCC technology. It excludes filters designed to be effective in the power line carrier (PLC) and radio interference spectra. The bulk of this document concentrates on the "conventional" AC filter technology and LCC (line-commutated converter) HVDC converters. The changes entailed by new technologies are also discussed. Voltage sourced converter (VSC) specific issues are discussed in CIGRE Technical Brochure 754 [1]2 and in IEC TR 62001-5 [2].
Contents:
- FOREWORD
- INTRODUCTION
- Scope