High-voltage switchgear and controlgear-Part 310: Electrical endurance testing for circuit-breakers above a rated voltage of 52 kV

$100.88 $201.76 -50%
Product Code: IEC TR 62271-310
Stock In Stock
Edition: 2.0
Published: 03/2008
Number of Pages: 46
File Size: 1 file, 1 Byte

Available Options

Product Description

High-voltage switchgear and controlgear – Part 310: Electrical endurance testing for circuit-breakers above a rated voltage of 52 kV

Introduction: Based on experience with existing high-voltage circuit-breakers in service and with system protection and maintenance policies, the majority of circuit-breaker applications are covered by class E1 as defined in 3.4.112 of IEC 62271-100. No additional tests for extended electrical endurance are required. However, extended electrical endurance (class E2) as defined in 3.4.113 of IEC 62271-100 should be considered for the following reasons: Field experience collected so far by CIGRE is limited only for circuit-breaker designs available before 1994 (see for example reference [1], [2], [3]1 and Annex A.3). For this reason, the data collected by CIGRE so far can hardly be extrapolated to new designs. Therefore, for new types of circuit-breakers, extended electrical endurance can only be fully proven by laboratory tests. New maintenance practices tend towards “maintenance-free” circuit-breakers. The reduction of maintenance costs is a major issue for most users today. Deregulation of the electricity market may increase the electrical stresses applied to the circuit-breakers, within their proven capability. Installation of generation capacity by independent power producers will increase short-circuit levels in certain areas and consequently change stresses on breakers. This may result in higher stresses applied to circuit-breakers compared to past practice when the short-circuit rating of the circuit- breaker was in large excess of the actual fault currents. There is a need to standa

Scope: This technical report is applicable to class E2 circuit-breakers above a rated voltage of 52 kV for use on overhead lines. The test programmes are based on accumulated electrical stresses due to current interruption during a period of 25 years, which was chosen as representative for a maintenance-free interval.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope