IEC TR 62296-2009 PDF

IEC TR 62296-2009 PDF

Considerations of unaddressed safety aspects in the second edition of IEC 60601-1 and proposals for new requirements

$239.59 $479.18 -50%
Product Code: IEC TR 62296
Stock In Stock
Edition: 2.0
Published: 01/2009
Number of Pages: 82
File Size: 1 file, 1 Byte

Available Options

Product Description

Considerations of unaddressed safety aspects in the second edition of IEC 60601-1 and proposals for new requirements

Introduction: At the Sydney meeting in August 1994, IEC subcommittee (SC) 62A established a procedure under which working group (WG) 14 would develop recommendations regarding problems of interpretation or application of IEC 60601-1. WG 14 is made up of experts with particular expertise in testing according to the requirements of IEC 60601-1. Many of the experts on WG 14 are employed by test houses with a long history of applying IEC 60601-1 to MEDICAL ELECTRICAL EQUIPMENT. While the National Committee members of SC 62A nominate these experts, their recommendations were not to be formally adopted through any official voting procedure. To reinforce this process, the Subcommittee specifically directed that the following note appear on every page of the resulting informational circular: IMPORTANT NOTE: Per the 62A decision at Sydney (see RM3755/SC62A, August 1994), the 62A Secretary is circulating this recommendation, prepared by 62A/WG14, regarding problems of interpretation or application of IEC 60601-1 to all P-Member NC’s. This recommendation/interpretation is the result of considerations by a group of nominated experts and has not been formally adopted through any NC voting procedure. Distribution is only for information. The plan approved in Sydney called for the 62A Secretary to circulate these recommendations to the member National Committees via an informational (INF) document. While the quality of the technical work of WG 14 is widely recognized and applauded, the overall process ha

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 2.2.10 Creepage distances and air clearances: Values under 1 mm
  • 2.2.11 Separation: Secondary circuit impedance limit LEAKAGE CURRENT
  • 2.2.12 ENCLOSURES and PROTECTIVE COVERS: Lampholder/switching device
  • 2.2.13 Fixing, prevention of maladjustment: Torque test
  • 2.2.14 Batteries not intended to be changed by OPERATOR: Lithium batteries
  • 2.2.15 Excessive temperatures: Ambient temperatures
  • 2.2.16 Continuous LEAKAGE CURRENTS: Different SUPPLY MAINS
  • 2.2.17 ENCLOSURE and protective covers: EQUIPMENT in ambulances
  • 2.2.18 Dielectric strength: Voltages appearing from external sources
  • 2.2.19 Testing switch mode power supply units (SMPSU)
  • 2.2.20 Failure of an electrical component: Time periodicity for detection
  • 2.2.21 Environmental conditions: Compliance paragraph
  • 2.2.22 Limitation of voltage and/or energy: Capacitance
  • 2.2.23 LEAKAGE CURRENTS: Presence of 45 kΩ resistor in Figure 21
  • 2.2.24 Humidity preconditioning treatment: Exception from requirement
  • 2.2.25 Dielectric strength: EQUIPMENT containing floating circuits
  • 2.2.26 General requirements for tests: Measurement uncertainty
  • 2.2.27 CREEPAGE DISTANCES and AIR CLEARANCES: Interpolated values
  • 2.2.28 Overheating: Change of load resistance
  • 2.2.29 Mains operated EQUIPMENT with additional power source: Integrity of
  • 2.2.30 Rechargeable batteries: No OPERATOR/USER maintenance
  • 2.2.31 Isolation from the SUPPLY MAINS: Symbol for single pole switch
  • 2.2.32 Sequence of testing: Clause 52 before Clause 19
  • 2.2.33 SINGLE FAULT CONDITION: ENCLOSURE LEAKAGE CURRENT from
  • 2.2.34 Marking on the outside of EQUIPMENT: Type and rating of fuses
  • 2.2.35 Excessive temperatures: APPLIED PARTS not intended to supply heat
  • 2.2.36 Mains supply transformers: Use of PTCs as protective devices

Be the first to write a review for this product.