Conductors of insulated cables – Data for AWG and KCMIL sizes
Introduction: Conductors described in IEC 60228 [1]1 are specified in metric sizes. North America and certain other regions at present use conductor sizes and characteristics according to the American Wire Gauge (AWG) system, and kcmil for larger sizes. The use of these sizes is currently prescribed across North America and elsewhere for installations by sub-national regulations. IEC TC 20 cable product standards do not prescribe cables with AWG/kcmil conductors. IEC TC 20 recognizes the need to produce a single, harmonized standard for conductors that is truly international. Harmonization, in this respect, is understood as the merging of AWG- based and metric-based sizes to produce one rationalized range of conductor sizes for power cables. TC 20 also recognizes that the development of such a harmonized standard is a long- term project. A three-stage approach, which will culminate in a single International Standard for conductors, has been agreed. Stage one of the approach is to produce a technical report that defines the range of AWG/kcmil sizes that are to be considered in the harmonization process. Stage two of the process is to develop this technical report by starting the rationalization process. The test methods and requirements in this technical report are to be aligned with those in IEC 60228. The third and final stage will be to produce a harmonized standard, based on IEC 60228 and the work of the first two stages, with a single, rationalized range of conductor sizes. The present
Scope: IEC/TR 62602, which is a technical report, specifies the nominal cross-sectional areas, in the range 20 AWG to 2 000 kcmil (0,52 mm2 to 1 010 mm2), for conductors in electric power cables and cords for a wide range of types. Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid and stranded copper, aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors. This technical report is not intended to apply to conductors designed for use in cables intended for telecommunication or data transmission, winding wires or similar products. Unless indicated to the contrary in a particular clause, this technical report relates to conductors in finished cables and not to conductors made or supplied for inclusion into a cable. The annexes give supplementary information covering measurement of resistance (Annex A), temperature correction factors for resistance measurement (Annex B) and dimensional limits of circular conductors (Annex C). Terms and definitions For the purposes of this document, the following definitions apply. 2.1 metal-coated coated with a thin layer of suitable metal, such as tin or tin alloy 2.2 nominal cross-sectional area value that identifies a particular size of conductor but is not subject to direct measurement NOTE Each particular size of conductor in this technical report is required to meet a maximum resistance value. Classification The conductors have been divided into four classes, 1, 2, 5 and 6. Those in Classes 1 and 2 are intended for use in cables for fixed installations. Classes 5 and 6 are intended for use in flexible cables and cords but may also be used for fixed installations: Class 1: solid conductors; Class 2: stranded conductors; Class 5: flexible conductors; – Class 6: flexible conductors which are more flexible than Class 5. – 20 – TR 62602 © CEI:2009 AVANT-PROPOS..................................................................................................................22 INTRODUCTION...................................................................................................................24 Domaine d’application
Contents:
- FOREWORD
- INTRODUCTION
- Scope