Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices
Introduction: This Technical Report is concerned with standards for high intensity therapeutic ultrasound (HITU) and concentrates on applications that destroy tissue by heating which may or may not be accompanied by acoustic cavitation and other mechanisms. The purpose of the report is to identify topics where there is a consensus that the development of international standards would benefit the industries and/or patients involved with these forms of therapeutic ultrasound. The shortcomings of existing standards as they may be related to the applications of interest are reviewed. It is not its purpose to propose or evaluate specific alternative measurement methods which may be more reliably applied to HITU or other therapeutic equipment. Physiotherapy and lithotripsy are excluded as there are existing standards for these established uses. Lower intensity applications such as enhanced bone healing or ultrasound-induced gene therapy are not explicitly considered. The use of HITU has advanced to the point where systems have achieved clinical approval for general use in several countries. Medical applications and product development are continuing rapidly. The corresponding products of many companies have been approved for marketing and clinical applications. Fast development in preclinical medicine, clinic medicine, and product manufacture has created an urgent need to standardize measurements of the basic acoustic parameters and the field characteristics of HITU. In order to promote the furt
Scope: This technical report is relevant to the measurement and specification of ultrasound fields intended for medical therapeutic purposes. Lithotripsy and physiotherapy are excluded, since there are existing International Standards for these applications. It establishes: topics where there is a consensus that the development of International Standards would benefit the industries and/or patients; topics where the writing of standards should start immediately; topics where the writing of technical specifications should start immediately in order to gain practical experience and establish consensus prior to standardisation; topics which require future standardisation but where further research is required before initiating the writing of standards or technical specifications. This report addresses primarily the requirements for measurement standards related to high intensity therapeutic ultrasound (HITU) [also known as high intensity focused ultrasound (HIFU)] fields which are both high intensity and focused and where the main mechanism for action is thermal. However, aspects of the discussion, conclusions and any resulting standards or technical specifications may also be relevant to therapeutic applications which are either focused or high intensity or where the main mechanism is not thermal. Scientific literature has been reviewed and responses to a questionnaire which was sent to experts around the world are reported. Background Recent years have seen a dramatic rise in interest in using ultrasound as a surgical and therapeutic tool in its own right. Much of this growth has been due to the use of High Intensity Therapeutic Ultrasound (HITU) for tissue ablation in the treatment of cancers and conditions such as benign prostate hyperplasia (BPH). Here, ultrasound is brought to a focus within tissue with the intention of generating intensity levels sufficient to raise the local tissue temperature above 55 °C. Like so much in ultrasound, this technique was first tested many years ago (Lynn et al, 1942; Wall et al, 1951, Fry et al, 1954), but recent materials, computing and other technological advances have allowed it to come close to the medical mainstream. The abilit
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 6.10 Tissue-mimicking material for QA/engineering evaluation
- 6.11 Electrical properties of the transducer
- 6.12 Treatment monitoring
- 6.13 Equipment safety and essential performance
- 6.14 Tissue properties