Performance of voltage sourced converter (VSC) based high-voltage direct current (HVDC) transmission – Part 1: Steady-state conditions
Introduction: High-voltage direct current (HVDC) is an established technology that has been in commercial use for more than 60 years. With the changes in demands due to evolving environmental needs, installation of HVDC systems has increased dramatically in the last 30 years and almost half of the world's HVDC projects were commissioned after the year 2000. HVDC has become a common tool in the design of future global transmission systems. An HVDC system transmits more electrical power over longer distances than a similar alternating current (AC) transmission system, which means fewer transmission lines are needed, saving both money and land and simplifying approvals. In addition to significantly lowering electrical losses over long distances, HVDC transmission is also very stable and easily controlled, and can stabilize and interconnect AC power networks that are otherwise incompatible. Typically, an HVDC system provides unique or superior capabilities in the following aspects: long distance bulk power transmission; asynchronous interconnections; long distance cable; controllability; lower losses; environmental concerns; limitation of short-circuit currents. The voltage sourced converter (VSC) HVDC transmission system is a new generation of HVDC transmission technology, which can increase the reliability of power grids and provide an alternative to connecting wind farms or solar farms to power grids, providing power to islands, connecting asynchronous grids and building direct current (DC)
Scope: The objective of this Technical Report is to present the "state of the art" with respect to general guidance on the steady-state performance demands of VSC HVDC transmission systems. It concerns the steady-state performance of two-terminal VSC HVDC transmission systems utilizing converters with power flow capability in both directions. Different configurations of a VSC HVDC transmission system are covered in this document, including the symmetrical monopolar, asymmetrical monopolar, bipolar with earth return, bipolar with dedicated metallic return and rigid bipolar configurations. There are many variations between different VSC HVDC transmission systems. This document does not consider these in detail; consequently, it cannot be used directly as a specification for a particular project, but rather to provide the general basis for the system steady-state performance demands. Normally, the performance specifications are based on a complete system including two VSC HVDC converter stations. However, sometimes a VSC HVDC transmission system can also be separately specified and purchased from multiple vendors instead of single turnkey vendor. In such cases, due consideration can be given to the coordination of each part with the overall VSC HVDC system performance objectives and the interface of each with the system can be clearly defined. The major components of the VSC HVDC transmission system are presented in IEC 62747. Referring to IEC 62747, an HVDC substation/converter station is defined as that part of the VSC HVDC transmission system which consists of one or more VSC converter units installed in a single location together with buildings, reactors, filters, reactive power supply, control, monitoring, protective, measuring and auxiliary equipment. The AC substations are not covered in this document. This document provides guidance and supporting information on the procedure for system design and the technical issues involved in the system design of VSC HVDC transmission projects for both owners and contractors. This document can be used as the basis for drafting a procurement specification and as a guide during project implementation.
Contents:
- FOREWORD
- INTRODUCTION
- Scope