Medical device software – Part 3: Process reference model of medical device software life cycle processes (IEC 62304)

Introduction: 0.1 Background Software is often an integral part of medical device technology. Establishing the safety and effectiveness of a medical device containing software requires well designed software that fulfils its purpose without causing any unacceptable risks. Following an internationally approved set of software development practices provides one way of achieving this. This technical report (TR) provides a framework of life cycle processes supporting the safe design and maintenance of medical device software called the process reference model (PRM). The process descriptions in this PRM are fully compliant with the requirements of ISO/IEC 24774:2010, Systems and software engineering – Life cycle management – Guidelines for process description. This TR presents the PRM for medical device software development as a result of integrating requirements from IEC 62304:2006 and from the international standard of software life-cycle processes ISO/IEC 12207:2008. This TR is aimed at medical device software developers who can use it for realizing the set of requirements they have to achieve to be compliant with IEC 62304:2006 in the scope of the safety class of the medical device software they are developing. Each process outcome with a corresponding safety class is a requirement in IEC 62304:2006. The process outcomes without a corresponding safety class are based only on ISO/IEC 12207:2008. These process outcomes provide additions that are beneficial when achieving the purpose of the pr

Scope: This part of IEC 80002, which is a technical report (TR), provides the description of software life cycle processes for medical devices. The medical device software life cycle processes are derived from IEC 62304:2006, with corresponding safety classes. They have been aligned with the software development life cycle processes of ISO/IEC 12207:2008 and are presented herein in full compliance with ISO/IEC 24774:2010. The content of these three standards provides the foundation of this TR. This TR does not address: areas already covered by existing related standards, e.g. the international standards that relate to the four standards used to build this TR (see Bibliography); FDA guidance documents; or software development tools. This TR describes the PRM for medical device software development and is limited in scope to the life cycle processes described in IEC 62304:2006. The process names correspond to those of IEC 62304:2006. The mappings provided in Annex B are essential for the alignment between IEC 62304:2006 (which is based on ISO/IEC 12207:1995) and ISO/IEC 12207:2008, developed to address the detailed normative relationship between the two standards. This technical report is not intended to be used as the basis of regulatory inspection or certification assessment activities.

Contents:

  • FOREWORD
  • INTRODUCTION
  • 0.1 Background
  • 0.2 Organization of this technical report
  • Scope