Rotating electrical machines – Part 2-3: Specific test methods for determining losses and efficiency of converter-fed AC induction motors
Introduction: The objective of this technical specification is to define test methods for determining the additional harmonic motor losses of converter-fed induction motors. These losses appear in addition to the losses on nominally sinusoidal power supply as determined by the methods of IEC 60034-2-1. Results determined according to this specification are intended to allow for comparison of the harmonic losses of different AC induction motors when fed by converters. In power-drive systems (PDS), the motor and the frequency converter are often manufactured by different suppliers. While motors of the same design are produced in large quantities, they may be operated from the grid or from frequency converters of many different types, supplied by many different manufacturers. The individual converter properties (switching frequency, DC link voltage level, etc.) may influence the system efficiency as well. It is impractical to determine the additional harmonic motor losses for every combination of motor, frequency converter, connection cable, output filter and parameter settings. Accepting that it is extremely difficult to specify motor efficiency for converter operation, this specification describes a limited number of approaches, depending on the voltage level and the rating of the machine under test. The procedures described in this specification result in a single number, the harmonic loss ratio rHL, which is the ratio of the additional harmonic motor losses and the motor losses measured u
Scope: This technical specification specifies test methods for determining losses and efficiencies of converter-fed AC induction motors within the scope of IEC 60034-1. The AC induction motor is then part of a variable frequency power drive system (PDS) as defined in IEC 61800-2, IEC 61800-4 or IEC/TS 61800-8. The additional harmonic losses determined by use of this technical specification are for comparison of different motor designs, but they are not appropriate to be used for efficiency determination of a PDS in a driven application with its wide range of torque versus speed operating points.
Contents:
- FOREWORD
- INTRODUCTION
- Scope