IEC TS 60079-42-2019 PDF

IEC TS 60079-42-2019 PDF

Explosive atmospheres Part 42: Electrical Safety Devices for the control of potential ignition sources from Ex-Equipment

$100.88 $201.76 -50%
Product Code: IEC TS 60079-42
Stock In Stock
Edition: 1.0
Published: 04/2019
Number of Pages: 52
File Size: 1 file, 1 Byte

Available Options

Product Description

Explosive atmospheres Part 42: Electrical Safety Devices for the control of potential ignition sources from Ex-Equipment

Introduction: Generally, the probability of potential ignition sources becoming effective is mitigated by applying the protection measures according to the IEC 60079 and the ISO 80079 series. If the probability of an ignition source becoming effective cannot be mitigated by these measures, it could be controlled by using a suitable safety device. The combination of the safety device and the Ex Equipment may then comply with the relevant standards of the IEC 60079 series and the ISO 80079 series with respect to the Equipment Protection Level. Safety devices, which are used as part of the protection of equipment for explosive atmospheres for control of potential ignition sources, should consider reliability for the intended purpose to recognise the principles for the classification of hazardous areas and explosion protection techniques. This document provides guidance for the application of safety functions to provide a reduction of ignition risk for equipment as part of the IEC 60079 series and ISO 80079 series. It relies on relevant IEC and ISO standards for safety related control systems.

Scope: This part of IEC 60079, which is a Technical Specification, provides guidance for equipment manufacturers where electrical safety devices are used to reduce the likelihood of potential ignition sources becoming effective in Ex Equipment located in Explosive Atmospheres. Electrical safety devices perform a safety function to control potential ignition sources from both, electrical or non-electrical Ex Equipment in explosive atmospheres. This document may also be applied to a combination of elements performing a safety function. For example: Sensor Logic system Final element This Technical Specification can also be used for assessing the safety device independently, without being designed for a specific Ex Equipment. A safety device can be a measure to achieve a required EPL of the Ex Equipment with respect to a potential ignition source. The combination of the safety device and the Ex Equipment could then comply with the relevant standards of the IEC 60079 series and the ISO 80079 series with respect to the Equipment Protection Level. However, increasing the EPL of Ex Equipment by the simple addition of a safety device is not within the scope of this document. This document does not apply to: mechanical control equipment such as pressure relief valves, mechanical governors and other mechanical safety devices the use of gas detection control equipment to prevent the occurrence of explosive atmospheres, e.g. inerting systems and ventilation systems mitigation of an explosion NOTE Some potential ignition sources might not be practicably controlled by safety devices. Electrical safety devices, where the level of safety integrity is identified under other parts of the IEC 60079 series, this document can be used as a reference for the realization of the level of safety integrity. Electrical safety devices may be installed either as part of or separate to the Ex Equipment under control (EEUC) and may be located inside or outside the hazardous area. – 8 – IEC TS 60079-42:2019 © IEC 2019

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TS 60079-42-2019 PDF

IEC TS 60079-42-2019 PDF

$100.88 $201.76