IEC TS 61463-2016 PDF

IEC TS 61463-2016 PDF

Bushings-Seismic qualification

$163.93 $327.86 -50%
Product Code: IEC TS 61463
Stock In Stock
Edition: 2.0
Published: 07/2016
Number of Pages: 44
File Size: 1 file, 778 Bytes

Available Options

Product Description

Bushings – Seismic qualification

Introduction: As it is not always possible to define accurately the seismic severity at the bushing flange level, IEC TS 61463, which is a Technical Specification, presents three alternative methods of qualification. The three methods are equally acceptable. If the required response spectrum (RRS) at the bushing flange is not known, a severity (in terms of acceleration values) based on standard response spectra at the ground level may be used to carry out qualification through one of the three methods described in this document. When the environmental characteristics are not sufficiently known, qualification by static calculation is acceptable. Where high safety reliability of equipment is required for a specific environment, precise data are used, therefore qualification by dynamic analysis or vibration test is recommended. The choice between vibration testing and dynamic analysis depends mainly on the capacity of the test facility for the mass and volume of the specimen, and, also if non-linearities are expected. When qualification by dynamic analysis is foreseen, it is recommended that the numerical model be adjusted by using vibration data (see Clause 5). This document was prepared with the intention of being applicable to bushings whatever their construction material and their internal configuration.The information contained, originally directed to porcelain bushings, has been partially updated to include also composite bushings.

Scope: IEC TS 61463, which is a Technical Specification, is applicable to alternating current and direct current bushings for highest voltages above 52 kV (or with resonance frequencies placed inside the seismic response spectrum), mounted on transformers, other apparatus or buildings. For bushings with highest voltages less than or equal to 52 kV (or with resonance frequencies placed outside from the seismic response spectrum), due to their characteristics, seismic qualification is not used as far as construction practice and seismic construction practice comply with the state of the art. This document presents acceptable seismic qualification methods and requirements to demonstrate that a bushing can maintain its mechanical properties, insulate and carry current during and after an earthquake. The seismic qualification of a bushing is only performed upon request.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TS 61463-2016 PDF

IEC TS 61463-2016 PDF

$163.93 $327.86