IEC TS 61966-13-2023 PDF

IEC TS 61966-13-2023 PDF

Multimedia systems and equipment-Colour measurement and management-Part 13: Measurement method of display colour properties depending on observers

$186.00 $371.99 -50%
Product Code: IEC TS 61966-13
Stock In Stock
Edition: 1.0
Published: 11/2023
Number of Pages: 54
File Size: 3 files, 1 Byte

Available Options

Product Description

Multimedia systems and equipment – Colour measurement and management – Part 13: Measurement method of display colour properties depending on observers

Introduction: In colorimetry, metamerism or metameric failure is defined as a perceived matching of two colours with different spectral power distributions (SPDs). Illuminant metamerism occurs when two objects match in colour under a specific illuminant, but mismatch under another illuminant with a different SPD. Likewise, observer metamerism (OM) is defined by two stimuli with different SPDs that match in colour for a specific observer. However, the stimuli might not match for another observer. OM is caused by the normal variations in the spectral responsivities of various observers. In other words, observers do not have identical colour-matching functions (CMFs). An observer model that takes into consideration the age and the field size of observers with respect to a standard observer standard observer has already been standardised in the CIE (CIE Pub. 170-1:2006). Meanwhile, display manufacturers and users have required measurement methods of the OM which occurs in display uses. For example, with the development of display technology and grafting of display technology to various application fields and mass distribution, it has become a common situation for users to use multiple displays at the same time. When using multiple displays at the same time, a user can display the same colour through the calibration process. However, this is only valid for certain observers because of OM. Also, when users watch a single display, there could be observer dependency in colour perception even thoug

Scope: This document defines an objective colour difference metric and a measurement method for observer metamerism caused by displays with different spectral power distributions. This document also specifies the measuring equipment, conditions and methods that are necessary to obtain the metric. This document applies to light-emitting or backlit transmitting colour displays measured under dark-room conditions.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TS 61966-13-2023 PDF

IEC TS 61966-13-2023 PDF

$186.00 $371.99