Ultrasonics – Field characterization – Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems
Introduction: The use of high intensity therapeutic ultrasound (HITU) has advanced to the point where systems have achieved clinical approval for general use in numerous countries. Medical applications and product development are continuing rapidly. Fast development in preclinical medicine, clinical medicine, and product manufacture has created an urgent need to standardize measurements of the basic acoustic parameters and the field characteristics of HITU. In order to promote the further development of HITU and to ensure its safe and effective use, common technical Specifications are required. This technical specification is relevant to the measurement and specification of ultrasound fields intended for medical therapeutic purposes. It addresses the requirements for high intensity therapeutic ultrasound (HITU) fields, including those generally referred to as high intensity focused ultrasound (HIFU). Lithotripsy and physiotherapy are excluded, since there are existing International Standards for these applications. As described in Annex A, because measurement at full output power from HITU systems still presents technical challenges, this standard specifies measurement methods at relatively low output levels and methodology for extrapolating these to higher therapeutic level fields.
Scope: This technical specification is applicable to high intensity therapeutic ultrasound (HITU) devices, specifying: relevant parameters for quantifying the field; measurement methods at relatively low output levels and methodology for extrapolating these to higher therapeutic level fields; consideration of sidelobes and pre-focal maxima; parameters relevant to HITU transducers of different construction and geometry, including non-focusing, focusing with or without lenses, collimated, diverging and convergent transducers, multi-element transducers, scanning transducers and multiple sources. This technical specification is intended to support the ultrasonic measurement requirements given in IEC 60601-2-62. These specifications would have use in quality assurance, safety testing, and the standardization of communications regarding the clinical performance of HITU systems. Where possible, this technical specification incorporates specifications from other related standards. This technical specification does not apply to the following types of devices, which are covered by other standards: lithotripters (see IEC 61846); surgical equipment (see IEC 61847); physiotherapy devices (see IEC 61689). Throughout this technical specification SI units are used. In the specification of certain parameters, such as beam-areas and intensities, it may be convenient to use decimal multiples or sub-multiples. For example, beam-area may be specified in cm2 and intensities in W/cm2 or mW/cm2.
Contents:
- FOREWORD
- INTRODUCTION
- Scope