Ultrasonics-Real-time pulse-echo scanners-Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)

$186.00 $371.99 -50%
Product Code: IEC TS 62558
Stock In Stock
Edition: 1.0
Published: 03/2011
Number of Pages: 54
File Size: 1 file, 2 Bytes

Available Options

Product Description

Ultrasonics – Real-time pulse-echo scanners – Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)

Introduction: This technical specification provides an example of a measurement method and of a test phantom. The specified method and test equipment permit operation without knowledge of proprietary information of the diagnostic ultrasonic equipment manufacturer. This technical specification describes desirable specifications and performance characteristics of a tissue-mimicking material (TMM) 3D artificial-cyst phantom. An example including design of a realized and conforming phantom is given. The described results are independent of applied electronic and design architecture of diagnostic ultrasound systems and related transducers suitable for testing with the phantom. Medical diagnostic ultrasound systems and related transducers need periodic testing as the quality of medical decisions based on ultrasonic images may decrease over time due to progressive degradation of essential systems characteristics. The TMM phantom is intended to be used to measure and to enable documentation of changes in void-detectability ratio in periodic tests over years of use. The example of phantom design uses sliced TMM arranged as alternating "cyst-slices" and "attenuation-slices". It allows measurement along all three axes of the ultrasonic beam (axial, azimuthal and elevation) to determine the void-detectability ratio depending on the depth in the image generated from a transducer. The basis of the design concept and measurement method is anechoic, artificial cysts, representing idealized pancreatic duct

Scope: This technical specification specifies essential characteristics of a phantom and method for the measurement of void-detectability ratio for medical ultrasound systems and related transducers. It is restricted to the aspect of long-term reproducibility of testing results. This technical specification establishes: important characteristics and requirements for a TMM 3D artificial cyst phantom using anechoic voids; a design example of a 3D artificial cyst phantom, the necessary test equipment and use of relevant computer software algorithms. This technical specification is currently applicable for linear array transducers. A uniformity test prior to void-detectability ratio (VDR) measurement is recommended. NOTE The basic concept of the 3D artificial-cyst phantom may also be valid for other types of ultrasound transducers; however there is a need for further verification (see Annex D).

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope