Marine energy – Wave, tidal and other water current converters – Part 30: Electrical power quality requirements
Introduction: Marine energy conversion systems, as viable electric power sources for utility and community- based applications, require close attention to the quality of the power produced. Poor power quality has negative impacts on both the electrical power source and the load. Therefore, guidance is needed for the manufacturer, developer and user on how to mitigate power quality issues during the design of the device. Electrical system planners also need to identify the requirements for grid integration of such variable and intermittent energy sources, while maintaining high reliability and power quality standards. Conceptually, except for wave energy convertors, many marine energy converter unit devices operate in a manner similar to wind turbines. As power quality is a mature topic within other renewable and conventional power generation schemes, there are numerous standards, codes, and guidelines in existence. In contrast, there are no standards or technical specifications for marine power generation systems that deal with the power quality issues and the associated integration needs. Therefore, this knowledge-gap needs to be addressed through incremental, detailed and collaborative standards development. This technical specification aims at: identifying power quality issues and parameters (non-device specific and non-prescriptive) for single/three-phase, grid-connected/off-grid (including micro-mini grid) marine wave, tidal and other water current converter-based power systems; estab
Scope: This part of IEC 62600 includes: definition and specification of the quantities to be determined for characterizing the power quality of a marine energy (wave, tidal and other water current) converter unit; measurement procedures for quantifying the characteristics of a marine energy (wave, tidal and other water current) converter. The measurement procedures are valid for a single marine energy converter (MEC) unit (or farm) with three-phase grid or an off-grid connection. The measurement procedures are valid for any size of MEC unit, though this document only requires MEC unit types intended for PCC (Point of Common Coupling) at Medium Voltage (MV) or High Voltage (HV) to be tested and characterized. In addition, a simplified measurement and reporting procedure is outlined for MEC units connected at Low Voltage (LV) networks. MV–connected and LV-connected devices are defined as: MV connected units – typically multiple three-phase MEC units operating as a marine power farm and delivering power through a HV or MV network; LV connected units – typically single-phase or three-phase units deployed in isolated, hybrid or micro-grid type systems supplying small-scale loads. Considering the nascent status of the marine energy sector, the following limitations of this document are to be recognized: voltage fluctuations under switching operation – the current revision only considers voltage fluctuations under continuous operation; resource classifications – to categorize the measured flicker quantities, various resource classes are suggested only as guidelines. The user is advised to use these resource classes judiciously. The measurement procedures are designed to be as non-site-specific as possible so that power quality characteristics measured at a test site, for example, can be considered valid at other sites also providing the same MEC unit configuration and operation modes (for example control parameters). If the configuration or operation mode is changed in any way that might cause the MEC unit to behave differently with respect to power quality, the power quality measurement procedures must be repeated. This document is for testing of wave, tidal and other water
Contents:
- FOREWORD
- INTRODUCTION
- Scope