Ultrasonics-Pulse-echo scanners-Simple methods for periodic testing to verify stability of an imaging system's elementary performance

$239.59 $479.18 -50%
Product Code: IEC TS 62736
Stock In Stock
Edition: 2.0
Published: 01/2023
Number of Pages: 70
File Size: 1 file, 6 Bytes

Available Options

Product Description

Ultrasonics – Pulse-echo scanners – Simple methods for periodic testing to verify stability of an imaging system's elementary performance

Introduction: An ultrasonic pulse-echo scanner produces images of tissue in a scan plane by sweeping a narrow, pulsed beam of ultrasound through the section of interest and detecting the echoes generated by reflection at tissue boundaries and by scattering within tissues. Various transducer types are employed to operate in a transmit/receive mode to generate/detect the ultrasonic signals. Ultrasonic scanners are widely used in medical practice to produce images of soft-tissue organs throughout the human body. As ultrasound systems are usually employed under rigorous time restrictions and in diverse environments to help make decisions that are often critical to patients' wellbeing, it is important that the systems perform consistently at the level initially provided and accepted in initial tests, for example, those of IEC TS 62791, IEC 61391-1, 61391-2, and IEC 62563-2. This document provides methods to verify the stability of an imaging system's elementary performance. This document is deemed necessary because substandard ultrasound-system performance is often accepted or remains undetected in the absence of unequivocal and documented tests. The most common of the failures, in all but the oldest systems nearing retirement, are sub- performance of a transducer-array element or lens or of a cable or electronic channel. There is approximately a 14 % transducer-failure rate and a 10 % system-failure rate per year on first testing [1],[2],[3],[4],[5],[5],[7],[8],[9],[10],[11],[12]1. Sensitive i

Scope: This document, which is a Technical Specification, specifies requirements and methods for periodic testing of the quality of diagnostic medical ultrasound systems using reflection-mode (pulse-echo) imaging. Image measurement and interpretation workstations are included. NOTE Usually, "periodic testing" is referred to as "quality control (QC)" or quality assurance (QA). This document includes minimum sets of such tests intended for frequent users of medical ultrasound systems, for quality assurance professionals in their organizations, or those hired from other quality-control and/or service-provider organizations. The procedures are for a wide range of more common diagnostic ultrasound systems, currently operating from 1 MHz to 40 MHz, although available phantoms meet the specifications only from 1 MHz to 23 MHz. The tests are defined in three levels, with the simplest and most cost-effective performed most frequently: Level 1 comprises five quick tests/observations to be performed daily to monthly by those normally operating the systems. Level 2 includes one necessary test for all systems in addition to those of Level 1, two Level 1 tests performed more rigorously, two tests that are for special situations or equipment, and one that is just optional, included because it is highly developed. Level 2 tests are performed annually by those with meaningful quality assurance training. Level 3 extends the two special situations tests to all systems, adds one optional test and includes a periodic review of the QA programme. Frequent distance-measurement accuracy tests are recommended in this document only for certain classes of position encoding that are not now known to be highly stable and without bias. QA in all dimensions is recommended in this document as the first test for such systems. The test methodology is applicable for transducers operating in the 1 MHz to 23 MHz frequency range. The types of transducers used with these scanners include a) electronic phased arrays, b) linear arrays, c) convex arrays, d) mechanical transducers, e) two-dimensional arrays operated in a 2D imaging mode, f) transducers operating in 3D imaging mode for a limited number of sets of

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope