Assessment of power quality - Characteristics of electricity supplied by public networks
Introduction: The description of electricity is of fundamental importance within electricity supply systems. In the past, its characteristics depended less on its generation than on the way in which it was transported by networks and being used by the equipment of the multiple users. Faults or other events such as short-circuit and lightning strikes occurring within users' installations or public networks also disturb or degrade it. Nowadays, smart grid construction and massive deployment of renewable energy sources increase the complexity of power quality management. For more information about power quality issues related to distributed generation and micro-grids, refer to Annex C. NOTE For more information about role of stakeholders for power quality management, see Annex G. There is a need for a common set of power quality (PQ) indices and measurement methods in order to allow different system operators to measure and report power quality in a consistent manner. Regarding the limits or levels of power quality, the situation differs. Historically, the electrical systems in different countries/ or regions have been designed in different ways to cater for national/ or regional variations like different geographic, climatic or commercial conditions, etc. It is thus essential that any set of internationally agreed power quality limits or levels also recognize these differences, which depends namely on the system configuration, the transfer characteristics between the different voltage levels
Scope: This document, which is a Technical Specification, specifies the expected characteristics of electricity at the point of supply of public low, medium and high voltage, 50 Hz or 60 Hz, networks, as well as power quality assessment methods. This document does not apply for systems operated above 230 kV. NOTE 1 The boundaries between the various voltage levels can be different for different countries/ or regions. In the context of this document, the following terms for system voltage are used: low voltage (LV) refers to UN ≤ 1 kV; medium voltage (MV) refers to 1 kV < UN ≤ 35 kV; high voltage (HV) refers to 35 kV < UN ≤ 230 kV. NOTE 2 Because of existing network structures, in some countries/ or regions, the boundary between medium and high voltage can be different. This document applies to the phenomena listed in Table 1. Table 1 – Classification of electromagnetic phenomena addressed by power quality indices Continuous phenomena Discontinuous phenomena – Events Other phenomena Frequency deviation Supply interruption Mains communicating voltages Supply voltage deviation Voltage dip Voltage unbalance Voltage swell Harmonic voltage Transient overvoltage Interharmonic voltage Rapid voltage change Flicker (voltage fluctuation) NOTE 1 Specification of related measurement methods can be found in IEC 61000-4-30. NOTE 2 Specification of the performance of related measuring instruments can be found in the IEC 62586 series. NOTE 3 For information on power quality phenomena at low voltage direct current (LVDC) network, refer to IEC TR 63282. While power quality is related to EMC in a number of ways, especially because compliance with power quality requirements depends on the control of cumulative effect of electromagnetic emission from all/ or multiple equipment and/or installations, this document is not an EMC publication (see also Annex E).
Contents:
- FOREWORD
- INTRODUCTION
- Scope