Industrial electroheating and electromagnetic processing equipment – Evaluation of hazards caused by magnetic nearfields from 1 Hz to 6 MHz

Introduction: An external alternating magnetic flux can induce electric fields inside the human body. Such induced fields constitute an important category of possible hazards. This technical specification deals with the sub-category of non-radiating magnetic nearfields in the frequency range between 1 Hz and 6 MHz being the source of the induced electric fields. The primary focus is on technical applications in industrial electroheating and electromagnetic processing installations and equipment, with the applicable safety standards in the IEC 60519 series. IEC 62110:2009 deals with measurement procedures applicable to the characterisation of magnetic and electric field levels with regard to public exposure. IEC 62822-2:2016 provides assessments of exposure restrictions for electric arc welding equipment from 0 Hz to 300 GHz. There is, however, no other IEC standard or technical specification covering more general kinds of equipment and hazard assessments in the range of up to 6 MHz. Magnetic field hazards are dependent on the source characteristics, including such without and with magnetic materials in the source circuit or workload. Such materials enhancing the magnetic flux density are required for creating an induced electric shock hazard below some few kHz. Static magnetic fields can cause other hazards than those by conventionally induced electric fields and are dealt with in IEC 60519-1:2015. The lower frequency limit in this technical specification is therefore 1 Hz. NOTE A parallel

Scope: This IEC technical specification specifies the characteristics of external magnetic nearfields, computations of and requirements on induced electric fields in body tissues in the frequency range from 1 Hz to 6 MHz with respect to induced electric shock phenomena, for electroheating (EH) based treatment technologies and for electromagnetic processing of materials (EPM). The phenomena include specific absorption rates with time integration. NOTE The overall safety requirements for the various types of equipment and installations for electroheating or electromagnetic processing in general result from the joint application of the General Requirements specified in IEC 60519-1:2015 and Particular Requirements covering specific types of installations or equipment. This technical specification complements the General Requirements and applies to internal frequency converters for creating high or low DC voltages, and to processing frequencies. Induced electric shock phenomena dealt with in this technical specification are caused by the alternating magnetic nearfield external to a current-carrying conductor or permeable object, inducing an electric field in a part of the body in the vicinity of the conductor. Relaxed criteria compared with the general basic restrictions for exposure apply. Simplified hazard assessment procedures apply for situations when only fingers, hands and/or extremities are in the magnetic nearfield. This technical specification does not apply to equipment within the scope of IEC 60519-9. i.e. equipment or installations for high frequency dielectric heating.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TS 62997-2017 PDF

IEC TS 62997-2017 PDF

$239.59 $479.18