Photovoltaic modules – Extended-stress testing – Part 1: Modules
Introduction: Existing qualification test standards such as IEC 61215 standard series have been very useful for identifying module designs that avoid most early field failures, but are not intended or able to demonstrate long term performance in all locations within the scope of those documents. In order to assess the risk of product failure it has become industry practice for the different stakeholders to require results of test protocols beyond baseline type approval and safety tests according to the IEC 61215 standard series and IEC 61730 standard series. These extended stress test protocols primarily contain aforementioned baseline tests in different sequences and/or increased test duration or number of cycles. They originate from the various experiences made by third parties such as test institutes/ independent engineering firms/ owners engineers and aim to cause aging that would be seen after long term use of PV modules, or apply a “test to failure” approach, aimed to identify weaknesses rather than to replicate field performance. They do not provide detailed reliability or durability predictions/estimates, but have been useful to reveal deficiencies. With many variants of extended stress test protocols in use, a standardized approach is desired. The included set of extended stress test sequences is intended to standardize the various approaches used by different industry participants, with a benefit of a common data set for reliability reviews, and a practical benefit to module manu
Scope: This document is intended to provide information to supplement the baseline testing defined in IEC 61215, which is a qualification test with pass-fail criteria. This document provides a standardized method for evaluating longer term reliability of photovoltaic (PV) modules and for different bills of materials (BOMs) that may be used when manufacturing those modules. The included test sequences in this specification are intended to provide information for comparative qualitative analysis using stresses relevant to application exposures to target known failure modes. A significant constraint imposed was that the test duration was limited, recognizing that customers of the test will proceed with decisions before the test results are available, if the test takes too long. With this business-relevant limitation, some known failure modes cannot be accurately addressed, most notably those related to long-term ultra-violet light (UV) exposures. While failure modes related to UV stress are known to occur on both front and back side of PV modules, the testing time required to achieve a dose of UV stress that causes changes observed in the field during the module’s intended lifetime without overstressing is beyond the scope of this document. The included backside UV stress sequence gives increased confidence for some backsheets with regard to backside cracking, and a frontside UV stress sequence is not included at all, leaving gaps for failure modes, such as encapsulant discoloration, frontside backsheet cracking, frontside delamination, etc. Other limitations of extended stress testing are described in Annex A. This document identifies vulnerabilities without attempting to gather the information needed to make a service-life prediction, which would require identifying failure mechanisms and their dependencies on all of the stresses. Annex B contains a brief background of the origins of the tests. Out of scope for this document is its use as a pass-fail criterion. The same module deployed in two different locations may fail/degrade in different ways, so a single test protocol cannot be expected to simultaneously exactly match both results, and will depend upon where and ho
Contents:
- FOREWORD
- INTRODUCTION
- Scope