Industrial networks - Ethernet-APL port profile / Ethernet-SPE profile specification
Introduction: IEEE Std 802.3TM-2022, Clause 146, specifies the Ethernet Physical Layer 10BASE-T1L, suitable to be used for full-duplex communication over a single balanced pair of conductors. This physical layer is specifically designed for industrial applications, supporting the main requirements for advanced, robust process control and monitoring in safe or hazardous areas. The primary physical layer solution focuses on four requirements: support of single pair cables providing both communication and optional power; increased data bandwidth, 10 Mbit/s; support of extended Ethernet cable length of up to 1 km; support of intrinsically safe protection for use in hazardous areas. IEEE Std 802.3-2022, Clause 146, only specifies the digital communication method and its electrical characteristics. To assure achieve interoperability between the various interconnected components at different parts of the network, a further set of specifications and classifications are supportive when applying this new physical layer for industrial applications requires a further set of specifications and classifications. The "Ethernet Advanced Physical Layer" (Ethernet-APL or APL) references and standardizes industrial automation extensions. In addition, IEEE Std 802.3TM-2022, Clause 104, as corrected and amended by IEEE Std 802.3dd-2022 specifies the Power over Data Lines (PoDL) of Single-Pair Ethernet. This clause specifies two optional power entities. These entities allow devices to supply or draw power using
Scope: This document is applicable to process automation equipment using a 10BASE-T1L compliant (see IEEE Std 802.3-2022, Clause 146) Physical Layer (PHY). Ethernet-APL intrinsically safe profiles with different predefined entity or limitation parameters (for example voltage, current, power, capacitance, inductance, cable length) simplify the examination of the interconnection of different Ethernet-APL ports. Furthermore, this document is also applicable to factory and building automation and control equipment using a 10BASE-T1L compliant, and Power over Data Lines (PoDL) compliant Physical Layer (PHY) for non-intrinsically safe Ethernet installations. NOTE In this document the term Ethernet-SPE is used for PoDL compliant PHY. The following technical features are part of this document: topology with trunk/ and spur installation capability; 2-wire technology (full-duplex communication data rate of 10 Mbit/s); long distance (refers to cable lengths of several hundred meters, with spans up to 1 000 m); intrinsic safety (installation of Ethernet-capable field devices in hazardous areas); power supply to field devices over the same 2-wire cable used for data communication; non-intrinsically safe Ethernet installation in factory and building automation.
Contents:
- FOREWORD
- INTRODUCTION
- Scope