A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation

Introduction: In the series of design verifications of IEC 61439-1 a temperature-rise verification of low-voltage power switchgear and controlgear assemblies (hereafter called ASSEMBLIES) is specified. This may can be by test, however, alternatives are acceptableunder defined circumstances. Selection of the method used for temperature-rise verification is the responsibility of the original manufacturer. Where applicable this document may can also be used for temperature-rise verification of similar products in accordance with other standards (e.g. IEC 60204-1). The method of calculation can also be used to determine the thermal power dissipation capability of an enclosure in accordance with IEC 62208 for a given internal air temperature-rise. The factors and coefficients, set out in this document have been derived from measurements on numerous assemblies and the method has been verified by comparison with test results.

Scope: This Technical Report specifies a method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation. The method is applicable to enclosed ASSEMBLIES or partitioned sections of ASSEMBLIES without forced ventilation. It is not applicable where temperature rise verification to the relevant product standard of the IEC 61439 series has been established NOTE 1 The influence of the materials and wall thicknesses usually used for enclosures can have some effect on the steady state temperatures. However, the generalised approach used in this technical report ensures it is applicable to enclosures made of sheet steel, sheet aluminium, cast iron, insulating material and the like. The proposed method is intended to determine the temperature rise of the air inside the enclosure. NOTE 2 The air temperature within the enclosure is equal to the ambient air temperature outside the enclosure plus the temperaturerise of the air inside the enclosure caused by the power losses of the installed equipment. Unless otherwise specified, the ambient air temperature outside the ASSEMBLY is the air temperature indicated for the installation (average value over 24 h) of 35 °C. If the ambient air temperature outside the assembly at the place of use exceeds 35 °C, this higher temperatureis deemed to be the ambient air temperature. This document specifies a method of air temperature-rise calculation inside enclosures for low- voltage switchgear and controlgear assemblies or similar products in accordance with their respective standard. The method is primarily applicable to enclosed assemblies or partitioned sections of assemblies without forced ventilation. However, some technical guidance to adapt it for the use of forced ventilation is given in this document. The results obtained by using this method are directly influenced by the accuracy of the evaluation of power losses used as inputs to perform the thermal calculations. NOTE The air temperature within the enclosure is equal to the ambient air temperature outside the enclosure plus the temperature-rise of the air inside the enclosure caused by the power losses of the installed equipment. For the me

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope