Performance of high-voltage d.c. (HVDC) systems Part 1: Steady-state conditions
Introduction: The difference between system performance specifications and equipment design specifications for individual components of a system is realized. Frequently, performance specifications are prepared as a single package for the two HVDC substations in a particular system. Alternatively, some parts of the HVDC system can be separately specified and purchased. In such cases, due consideration is given to coordination of each part with the overall HVDC system performance objectives and to ensuring that the interface of each with the system is clearly defined. Typical of such parts, listed in the appropriate order of relative ease for separate treatment and interface definition, are: a) DC line, electrode line and earth electrode; b) telecommunication system; c) converter building, foundations and other civil engineering work; d) reactive power supply including AC shunt capacitor banks, shunt reactors, synchronous and static reactive power (var) compensators; e) AC switchgear; f) DC switchgear; g) auxiliary systems; h) AC filters; i) DC filters; j) DC reactors; k) converter transformers; l) surge arresters; m) series commutation capacitors; n) valves and their ancillaries; o) control and protection systems. NOTE The last four items are the most difficult to separate, and, in fact, separation of these four can be inadvisable. Clause 4 to Clause 22 of this document set out a complete steady-state performance specification for an HVDC system. Since the equipment items are usually separa
Scope: This part of IEC 60919 provides general guidance on the steady-state performance requirements of high-voltage direct current (HVDC) systems. It concerns the steady-state performance of two-terminal HVDC systems utilizing 12-pulse converter units comprised of three-phase bridge (double-way) connections (see Figure 1), but it does not cover multiterminal HVDC transmission systems. Both terminals are assumed to use thyristor valves as the main semiconductor valves and to have power flow capability in both directions. Diode valves are not considered in this document. Key Transformer valve windings Figure 1 – Twelve-pulse converter unit Only line-commutated converters are covered in this document, which includes capacitor commutated converter circuit configurations. General aspects of semiconductor linecommutated converters are given in IEC 60146-1-1, IEC TR 60146-1-2 and IEC 6014613. Voltage-sourced converters are not considered. The distinction is made between system performance specifications and equipment design specifications for individual components of a system. Equipment specifications and testing requirements are not defined in this document. Also excluded from this document are detailed seismic performance requirements. In addition, because there are many variations between different possible HVDC systems, this document does not consider these in detail; consequently, it is not used directly as a specification for a particular project, but rather to provide the basis for an appropriate specification tailored to fit actual system requirements. This document, which covers steady-state performance, is followed by the additional documents of IEC TR 60919-2 on faults and switching as well as IEC TR 60919-3 on dynamic – 12 – IEC TR 60919-1:2020 © 2020 conditions. All three aspects are considered when preparing twoterminal HVDC system specifications.
Contents:
- FOREWORD
- INTRODUCTION
- Scope