Electromagnetic compatibility – Part 2-15: Description of the characteristics of networks with high penetration of power electronic converters
Introduction: IEC 61000 is published in separate parts according to the following structure: Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (insofar as these limits do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part is further subdivided into several parts, published either as international standards or as technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: IEC 61000-6-1). This part of IEC 61000-2 describes the main phenomena which affect the power quality of modern distribution systems with high penetration of power electronics converters. It focuses on the following main aspects: resonances in LV network, impact of increased number of power electronic converters, instability issues for the equipment to be connected to the LV networks. Those new aspects, organized and described in this document, can lead to new IEC specifications; that is why a state of the art
Scope: This part of IEC 61000, which is a Technical Report, addresses in particular the following main phenomena, which affect the power quality in modern distribution systems with high penetration of power electronics converters. As some aspects of the subject have already been addressed in the past, considering the evolution of the LV and MV networks, this document focuses on the following aspects: resonances in the network, modelling and on-site validation; supraharmonics and measurements issues; impact of increased number of power electronic converters; stability and instability issues for the equipment to be connected The target phenomena and conditions of this document are the following: frequency: ≤ 2 kHz, 2 kHz to 9 kHz, ≥ 9 kHz; voltage levels: LV, MV; harmonic sources: all types of converters (EV battery chargers, appliances, etc.…). Some of these frequency ranges have already been standardized in some countries (Japan, Germany, Switzerland, etc.), but the resulting phenomena developed will benefit being described in more details, with a focus on the interaction between the converters and the electrical networks. The case of the presence of a large number of converters is also at stake. Some complex phenomena can also arise when the full system is not stable anymore. NOTE Whereas it is expected that the models and derived calculations form this document can be applied to the Americas electrical systems its formal validation studies are still pending.
Contents:
- FOREWORD
- INTRODUCTION
- Scope