Ultrasonics – Real-time pulse-echo systems – Test procedures to determine performance specifications
Introduction: An ultrasonic pulse-echo scanner produces images of tissue in a scan plane by sweeping a narrow, pulsed beam of ultrasound through the section of interest and detecting the echoes generated at tissue boundaries. Furthermore, the number of ultrasonic pulse-echo scanners using plane-wave imaging technology is increasing. Alternatively, a scanner can transmit a wide-field wave-front or several transmit-beams and record from the whole transducer array the echoes backscattered from tissue boundaries [1] [2]1. The latter is followed by software beamforming, picking several parts of the wide beam or in this way selecting one of the simultaneously transmitted beams to obtain adequate resolution. Plane-wave techniques cannot compete with physical, transmit beam-forming for maximum depth of imaging at a given bandwidth, maximum resolution and minimum acoustic exposure. Ultrasonic scanners are widely used in medical practice to produce images of many soft-tissue organs throughout the human body. A variety of transducer types is employed to operate in a transmit/receive mode for generating/receiving the ultrasonic signals. This document describes test procedures that should be widely acceptable and valid for a wide range of types of equipment. Manufacturers should use this document to prepare their own specifications, while users should use this document to check manufacturers’ specifications. The measurements can be carried out without interfering with the normal working conditions of t
Scope: This document describes representative methods of measuring the performance of complete real-time medical ultrasonic imaging equipment in the frequency range 0,5 MHz to 23 MHz. NOTE The frequency range given represents, in general, the widely used range in hospitals at the date of publication; special medical applications use higher frequencies for imaging but mainly in research or pre-clinical imaging. This document is relevant for real-time ultrasonic scanners based on the pulse-echo principle, for the types listed below: mechanical sector scanner; electronic phased array sector scanner; electronic linear array scanner; electronic curved array sector scanner; water-bath scanner based on any of the above four scanning mechanisms; plane-wave/fast imaging scanners; combination of several of the above methods (e.g. a linear array phased at the edge to produce a sector there to enlarge the field of view. The methods described are based on evaluation of: sonograms obtained by scanning of tissue mimicking objects (phantoms); sonograms obtained by scanning of artificial, low- or highly reflective targets in suitable environments; parameters of the ultrasound field transmitted by the measured scanner. This document does not relate to methods for measuring electrical parameters of the scanner’s electronic systems.
Contents:
- FOREWORD
- INTRODUCTION
- Scope