Mineral insulating oils – Oxidation stability test method based on differential scanning calorimetry (DSC)
Introduction: The existing methods to assess oxidation stability of mineral insulating oil are very time consuming. A faster method is necessary for effective quality control and status monitoring. Differential scanning calorimetry (DSC) as a technique has been used for monitoring grease and lubricants oxidation stability. The use of DSC for evaluation of oil oxidation stability was originally suggested to IEC, TC 10 following publication of a literature review of DSC oxidation tests performed on petroleum products (10/367/INF April 1996). During IEC’s TC 10 meeting in Geneva, 1998, it was decided to set up a working group for development of a standard based on DSC for rapid evaluation of mineral insulating oil oxidation stability.
Scope: The purpose of IEC 62036, which is a technical report, is to develop a rapid oxidation stability test method based on differential scanning calorimetry (DSC) to assess the oxidation stability of mineral insulating oils. General remarks The main function of insulating oil is insulation and cooling. The expected life span of transformer oil is 25 to 40 years, largely depending on operating temperature and electrical load. Specifications are prepared and used to fulfil all criteria required for proper functioning of the oil in service. Life expectancy from insulating oil has a large economic impact on the cost of operation of a unit. The oxidation stability test is an important test as this will evaluate, to some extent, the life of the oil in service. Resistance of an oil oxidation is very much dependant on the refining process and type of crude oil. Both under-refined and over-refined oils may exhibit poor oxidation stability. The complex process of oxidation of in-service oils occurs slowly at the normal operating temperature of the transformer and is dependant on temperature, oxygen and catalyst. In the first stage of oil oxidation, radicals and peroxides are produced. These compounds are unstable and rapidly convert to volatile and soluble acids and finally producing insoluble material or sludge. All of these products have an adverse effect on electrical and physical properties of oil. The oil may reach a stage where it is not fit for its intended purpose. To establish a long service life for the oil, an oxidation stability test is performed on the unused oil. There are several standard test methods for evaluation of the oxidation stability of transformer oil. The recommended international test method is IEC 61125. This test involves oxidizing the oil at 120 °C for 164 h and then measuring the acidity, sludge and dielectric dissipation factor (DDF). Other national test methods are based on the same principal and are time consuming. On delivery, it is required to test the oil for compliance with the specification. As this test is very time consuming, results are usually retrospective. Clearly, existing methods are time consuming and not very sensitive. Although
Contents:
- FOREWORD
- INTRODUCTION
- Scope