Medical devices – Part 2: Guidance on the application of usability engineering to medical devices
Introduction: This technical report provides MEDICAL DEVICE MANUFACTURERS with guidance on how to integrate USABILITY ENGINEERING (also called HUMAN FACTORS ENGINEERING) principles and USER INTERFACE design practices into their overall MEDICAL DEVICE development PROCESSES. The technical report recognizes that all MEDICAL DEVICES involving human interaction present opportunities for optimization through the application of USABILITY ENGINEERING and seeks to guide the MEDICAL DEVICE MANUFACTURERS efforts. This report concerns the quality of USER interactions with MEDICAL DEVICES that are as varied as acquiring information on a display, pressing a physical button or on-screen touch target button, selecting items on a software menu, attaching ACCESSORIES to a MEDICAL DEVICE and interpreting warnings as well as understanding relevant aspects for the proper use of the MEDICAL DEVICE by reading the ACCOMPANYING DOCUMENTATION. USABILITY ENGINEERING programs, if properly implemented, can increase the likelihood that USERS are able to perform such actions correctly and without hindrance. Medical practice is increasingly using MEDICAL DEVICES for observation and treatment of PATIENTS. USE ERRORS caused by inadequate MEDICAL DEVICE USABILITY have become an increasing cause for concern. Many of the MEDICAL DEVICES developed without applying a USABILITY ENGINEERING PROCESS are non-intuitive, difficult to learn and difficult to use. In addition, MEDICAL DEVICES developed without applying USABILITY ENGINEE
Scope: This Part of IEC 62366, which is a Technical Report, contains background information and provides guidance that addresses specific areas that experience suggests can be helpful for those implementing a USABILITY ENGINEERING (HUMAN FACTORS ENGINEERING) PROCESS both as defined in IEC 62366-1:2015 and as supporting goals other than SAFETY. This technical report is not intended to be used for regulatory purposes. It contains no requirements and only provides guidance and tutorial information. NOTE 1 SAFETY is freedom from unacceptable RISK, which is described in ISO 14971. Unacceptable RISK can arise from USE ERROR, which can lead to exposure to direct physical HAZARDS or to loss or degradation of clinical performance. NOTE 2 The PROCESS for a MANUFACTURER to analyse, specify, develop and evaluate the USABILITY of a MEDICAL DEVICE, as it relates to SAFETY is found in IEC 62366-1:2015. This technical report has two main themes: information about efficient ways to implement elements required by IEC 62366-1:2015; and additional information, in particular how USABILITY relates to attributes such as TASK EFFICIENCY and USER satisfaction, which can enhance a MEDICAL DEVICE’S commercial success. This technical report discusses the business benefits of USABILITY ENGINEERING, the basics of applicable analysis and design techniques, MEDICAL DEVICE USABILITY EVALUATION approaches, efficient ways to address USABILITY ENGINEERING project implementation issues (e.g. integration into a quality management system) and provides a list of useful USABILITY ENGINEERING resources. This technical report also can be useful for other healthcare products (e.g. drug packaging and drug LABELLING, drug-MEDICAL DEVICE combination products and health IT software). 1.2 Purpose The intent of this technical report is to provide guidance related to: the essential elements of USABILITY ENGINEERING PROCESS as required by IEC 62366-1:2015, including: USER research techniques, analysis techniques, design techniques, and MEDICAL DEVICE USABILITY EVALUATION approaches (e.g. USABILITY TESTING); the planning and implementation of the USABILITY ENGINEERING PROCESS; the benefits of applying USABILITY ENGINEERI
Contents:
- FOREWORD
- INTRODUCTION
- Scope