IEC TR 62614-2-2015 PDF

IEC TR 62614-2-2015 PDF

Fibre optics-Multimode launch conditions-Part 2: Determination of launch condition requirements for measuring multimode attenuation

$163.93 $327.86 -50%
Product Code: IEC TR 62614-2
Stock In Stock
Edition: 1.0
Published: 07/2015
Number of Pages: 40
File Size: 1 file, 1.2 MB

Available Options

Product Description

Fibre optics – Multimode launch conditions – Part 2: Determination of launch condition requirements for measuring multimode attenuation

Introduction: At the meeting of IEC TC86 and its subcommittees and working groups in Cape Town in 2005, there were numerous discussions regarding measurements on multimode fibres, cables, passive components and cable plants. Liaisons were also received from ISO/IEC JTC1 SC25 WG3 that reported on the requirements of ISO/IEC14763-3 for testing fibre optic cabling in premises cabling. This Technical Report used a mode power distribution template in an attempt to control the launch conditions at the location of the reference connector to improve measurement accuracy and reduce uncertainty when testing the attenuation of multimode fibre optic cabling. IEC SC86B had also adopted the metric. It was decided to set up a “Multimode Launch Co-ordinating Group” referred to as MMLCG. This would be set up directly reporting to IEC TC86 and include representatives from interested persons in subcommittees 86A, 86B and 86C as well as ISO/IEC JTC1 SC25 WG3. The scope of the MMLCG was defined as: “To coordinate the harmonization of the variety of multimode modal launch conditions that exist within the documents being prepared and published by the subcommittees of IEC TC86 for the purpose of attenuation and return loss measurements.” The intent of this Technical Report is to keep available the key technical aspects issued by the MMLCG. The key documents used in the developmental of this Technical Report have been retained and are stored on the IEC collaboration tools for reference.

Scope: IEC TR 62614-2, which is a Technical Report, is intended to show the background of encircled flux for the characterization of multimode launch conditions. This includes the selection of the encircled flux and the definition of the encircled flux requirements in conjunction with the implied variation for all multimode attenuation and return loss measurement methods on graded index multimode fibre products.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 62614-2-2015 PDF

IEC TR 62614-2-2015 PDF

$163.93 $327.86