IEC TR 62797-2013 PDF

IEC TR 62797-2013 PDF

International comparison of measurements of the magnetic moment using vibrating sample magnetometers (VSM) and superconducting quantum interference device (SQUID) magnetometers

$163.93 $327.86 -50%
Product Code: IEC TR 62797
Stock In Stock
Edition: 1.0
Published: 08/2013
Number of Pages: 36
File Size: 1 file, 574 Bytes

Available Options

Product Description

International comparison of measurements of the magnetic moment using vibrating sample magnetometers (VSM) and superconducting quantum interference device (SQUID) magnetometers

Introduction: Following a proposal made at the meeting of IEC TC 68 Working Group 2 (Magnetic alloys and steels – Measuring methods) in Braunschweig (PTB, 13-14 November 2006), an intercomparison exercise was started regarding the measurement of the magnetic moment by means of the vibrating sample magnetometer (VSM) method. The VSM finds widespread use in industrial and research laboratories, because of its sensitivity, ruggedness, and relative simplicity of use [1]1. It is not an absolute method and requires calibration by means of a reference sample. This is typically represented by a very pure Ni sphere, calibrated by means of an independent method [2]. The VSM is generally applied for the characterization of hard magnetic materials, but, depending on the specific sensitivity of the apparatus, can also be used to test paramagnetic and diamagnetic materials. Its application to magnetically soft materials is generally restricted to the determination of the saturation magnetization. In fact, being an open circuit method, the VSM is not suited to the measurement of the magnetization curve of soft magnetic materials. The basic aim of this comparison is to verify the degree of reproducibility of the method, a prerequisite for the prospective development of a related IEC measuring standard. The existing ASTM Standard A894/894M-00 [3] is devoted to the determination of the saturation magnetization of nonmetallic magnetic materials. Ten different research laboratories, listed in Annex B, agreed

Scope: This Technical Report provides the results of an international comparison of measurements of the magnetic moment, using vibrating sample magnetometers (VSM) and superconducting quantum interference device (SQUID) magnetometers. The basic object of this comparison is to verify the degree of reproducibility of the method employed as a prerequisite for the prospective development of a related IEC measuring standard. Overview In this report an intercomparison exercise on the measurement of the magnetic moment by means of the vibrating sample magnetometer (VSM) and superconducting quantum interference device (SQUID) magnetometer is presented. The VSM finds widespread use in industrial and research laboratories, because of its sensitivity, ruggedness, and relative simplicity of use. The basic aim of this comparison was to verify the degree of reproducibility of the VSM method, as a prerequisite for the prospective development of a related IEC measuring standard. At present time, the VSM method is invoked in the ASTM Standard A984, which is devoted, however, exclusively to the determination of the saturation magnetization of nonmetallic magnetic materials. An exercise was carried out by ten different laboratories regarding the measurement of the hysteresis loop parameters in hard ferrites and the magnetic moment in tape samples by means of the VSM (SI units). Each laboratory was assumed to have appropriate traceability of measurements and was required to determine the measurement uncertainty according to the ISO/IEC Guide to the expression of uncertainty in measurement. The comparison was coordinated by INRIM. The results were analyzed according to standard rules (e.g. ISO and EURAMET guidelines). The following relative standard deviations of the laboratories best estimates around the unweighted mean were found: a) Anisotropic hard ferrites: coercive field HcJ ∼ 1,0 %; coercive field HcB ∼ 0,9 %; polarization at applied field Ha ∼ 800 kA/m J800k ∼ 0,80 %; remanent polarization Jr ∼ 1,8 %; maximum energy product (BH)max ∼ 1,2 %. b) Isotropic hard ferrites: coercive field HcJ ∼ 1,0 %; coercive field HcB ∼ 3,5 %; polarization at applied field Ha = 800 kA/m J800k ∼ 1,2 %;

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 62797-2013 PDF

IEC TR 62797-2013 PDF

$163.93 $327.86