Electrochemical migration in printed wiring boards and assemblies – Mechanisms and testing
Introduction: Electronic products including components nowadays are designed to satisfy the demands for miniaturization, high functionality and environmentally friendly products. Various types of degradation occur in the electronic products used in the field. Appropriate measures are required to mitigate such degradation from the standpoint of reliability assurance. A study has been carried out to develop the understanding of the phenomenon and has proposed test methods for electrochemical migration with the purpose of suppressing the migration in products used in the field. This Technical Report is related to electrochemical migration including conductive anodic filament (CAF). Specifically, it explains: the preliminary test: the steady state temperature humidity test, the temperature humidity cycle test, the unsaturated pressurized vapor test, the saturated pressurized vapor pressure test, the dew condensation cycle test and the water drop test; the insulation resistance measurement method: manual measurement, automatic measurement, a dielectric characteristics method, and an AC impedance method. Moreover, the difference between the measurement while the specimen is kept in the testing environment and not taken out of the chamber for measurement, and the measurement of the resistance of a specimen while it is taken out of the test chamber, and the merit of an automatic measurement are also described; the equipment used for analysis, the observation method of a failure part, and examples
Scope: This Technical Report describes the history of the degradation of printed wiring boards caused by electrochemical migration, the measurement method, observation of the failure and remarks to testing in detail. Electrochemical migration NOTE Electrochemical migration is sometimes called ion migration. In this technical report electrochemical migration/ion migration will be referred to as migration. 2.1 Operation failure of electronic and electric equipment It is known that failures caused by various degradation phenomena occur in electric and electronic products while they are used in the field. Causes of such failures are classified in Figure 1. The causes may be classified into: electric, thermal, mechanical and electrochemical origins. They are entwined with each other. The environment in which equipment is used also affects the generation of failures. Growth of an electrically conducting filament caused by migration will short-circuit two conductors when a bias voltage is applied between them and will lead to a malfunctioning in the equipment. Figure 1 – Main causes of insulation degradation in electronic equipment Electric Environmental Corrosion Chemical treeing Electrochemical Mechanical Whisker Crack Interfacial -separation Electrochemical migration Partial discharge Electrical treeing Water treeing Tracking Arc Chemical and thermal IEC 1272/14 – 92 – IEC TR 62866:2014 © IEC 2014 AVANT-PROPOS .................................................................................................................. 97 INTRODUCTION ................................................................................................................... 99 Domaine d'application ................................................................................................. 100 Migration électrochimique ............................................................................................ 100 2.1 Défaillance de fonctionnement des matériels électroniques et électriques ........... 100 2.2 Changement de nom de la migration provoquant une dégradation d'isolement et nature de la dégradation ............................................................... 101 Histoire de la
Contents:
- FOREWORD
- INTRODUCTION
- Scope