Device embedded substrate – Part 2-2: Guidelines – Electrical testing
Introduction: Current electrical package designs are becoming more complex, more functionally integrated, more reliable and more miniaturized than ever. Hence, electrical tests should be classified into levels in order to ensure the performance and quality of device embedded substrates since the substrate contains active/passive devices within it. While the interconnection open/short test is enough for general substrates, functional tests should be done when active/passive devices are embedded inside the substrate. However, the main problem is that we need to understand which devices are embedded and how they are connected functionally to each other. This is the main reason that there should be standardized test methods for device embedded substrate. Figure 1 shows the existing substrate test method: the interconnection open/short test. a) Open test b) Short test Figure 1 – Interconnection open/short test IEC P1 P2 IEC P1 P2
Scope: This part of IEC 62878, which is a Technical Report, describes the necessary information on electrical testing for device embedded substrate. This includes the interconnection open- and short-circuit tests as well as the device functional test. It also provides guidelines by demonstrating the electrical test for device embedded substrate. This part of IEC 62878 is applicable to device embedded substrates fabricated by use of organic base material, which include for example active or passive devices, discrete components formed in the fabrication process of electronic wiring board, and sheet formed components. The IEC 62878 series does not apply to the re-distribution layer (RDL) nor to the electronic modules defined as an M-type business model in IEC 62421. Electrical tests 2.1 Test level 1A for device embedded substrate Test level 1A for device embedded substrate is to check the continuity and isolation of interconnections which are not connected to any embedded components. This is shown in Figure 2. Test point 1 and test point 2 are on different networks. After measuring the resistance between net 1 and net 2, it can be found that net 1 and net 2 are short if the measured resistances are below a certain resistance. Test point 3 and test point 4 are on the same net, which is net 3. They are open if the measured resistance between the two test points is over a certain resistance. It means that they are not electrically connected. Multi-testers which can measure voltage and current are commercially available. The source meter can measure the resistance directly since it has its own power supply. In terms of reliability, a high-current or low-level voltage test can be done to check the micro-open which causes the latent defects in the printed-circuit board and to check the micro-short which causes noise in the RF system. – 16 – IEC TR 62878-2-2:2015 © IEC 2015 AVANT-PROPOS .................................................................................................................. 17 INTRODUCTION ................................................................................................................... 19 Domaine d'application .........................
Contents:
- FOREWORD
- INTRODUCTION
- Scope