IEC TR 63139 (REDLINE + STANDARD)-2026 PDF

IEC TR 63139 (REDLINE + STANDARD)-2026 PDF

Explanation and background information on electrical safety requirements in TC 34 standards

$171.50 $342.99 -50%
Product Code: IEC TR 63139 (REDLINE + STANDARD)
Stock In Stock
Edition: 2.0
Published: 03/2026
Number of Pages: 50
File Size: 1 file

Available Options

Product Description

Explanation and background information on electrical safety requirements in TC 34 standards

Introduction: This document provides background information to the following subjects being introduced into IEC TC 34 standards to cover new technologies associated with the use of LED light sources and controllable products. This document consists of the following subdivisions: Clause 4 - Mathematical addition of working voltages Calculation of increased working voltage in case of insulation failure; Clause 5 - Insulation between circuits following the circuits analysis in Clause 6; Clause 7 - Use of protective extra low voltage (PELV); Clause 8 - Insulation between LV supply and control line conductors; Clause 9 - Summation of touch currents in a connected lighting system; Clause 10 - Examples of insulation coordination situations between controlgear and luminaire.

Scope: This document is related to the insulation coordination in TC 34 standards and provides explanations on mathematical addition of working voltages, insulation between circuits, use of protective extra low voltage (PELV) and insulation between LV supply and control line conductors in order to cover new technologies associated with the use of LED light sources and controllable products. It describes in which way the addition of supply voltages and working voltages can be arranged for an assessment of the electrical insulation requirements (e.g. creepage distances and clearances) in a system if a first failure occurs. Furthermore the actual failure scenarios given in IEC 60598-1:2014 and IEC 60598- 1:2014/AMD1:2017, Annex X and IEC 61347-1:2015, Clause 15 are explained in greater detail and the rationale behind the protective requirement for each situation is given (e.g. possible LV primary to ELV secondary does not lead to an overburden of the insulation in the second circuit). This document also describes the possibility to increase immunity and reliability of electronic circuits, used in combination with LEDs, with the use of PELV and the associated safety consequences for this system. The insulation between LV supply and control line conductors is also important and this document explains why this is an essential safety consideration for a complete installation system. This document provides explanations and background information on electrical safety requirements in TC 34 standards.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TR 63139 (REDLINE + STANDARD)-2026 PDF

IEC TR 63139 (REDLINE + STANDARD)-2026 PDF

$171.50 $342.99