Power quality management – Part 100: Impact of power quality issues on electric equipment and power system
Introduction: The impacts of power quality issues increasingly attract much attention with modern industrial development. The integration of nonlinear loads, such as power-electronic based equipment, electric arc furnace, electric locomotive, etc., and faults or other events such as short-circuit and lightning strikes directly or indirectly cause power quality issues. If public supply system power quality is not within the reasonable range defined in IEC TS 62749, and/or the demand-side power quality is not appropriately managed (e.g. IEC TR 63191) and/or the equipment immunity does not accommodate the expected environment, the performance of equipment may be impacted, likely causing malfunction, maloperation, or damage, and likewise the power system itself. On the other hand, the quality of power is not absolute. Regarding the levels of power quality, the situation differs. So called “poor” power quality level for one grid may be acceptable or good for another internal application depending on the system configuration, the transfer characteristics between the different voltage levels (attenuation or amplification), the immunity of the equipment /installations/appliances, the actual disturbance levels on the system, etc. In terms of power quality, the situation in micro-grid on islanding mode, off grid, mini-grid or weak grid may differ from that in public supply system. The level of power quality may worsen even far outside the recommended values defined by IEC TS 62749. In those forement
Scope: This part of IEC 63222, which is a Technical Report, collects relevant information on power quality impacts from, e.g., CIGRE reports, case studies, research findings, etc., in order to uncover the mechanisms of how electrical equipment/installations/system are impacted by power quality disturbances, as well as to fully understand the guidelines for power quality management. The contents of this document aim to help network operators, network users and equipment suppliers make rational investments and actively cooperate to manage power quality and keep it consistent with relevant EMC standards. NOTE 1 The boundaries between the various voltage levels may be different for different countries/regions. In the context of this document, the following terms for system voltage are used: low voltage (LV) refers to UN ≤ 1 kV medium voltage (MV) refers to 1 kV < UN ≤ 35 kV high voltage (HV) refers to 35 kV < UN ≤ 230 kV NOTE 2 Because of existing network structures, in some countries/regions, the boundary between medium and high voltage can be different.
Contents:
- FOREWORD
- INTRODUCTION
- Scope