IEC TS 60079-48-2023 PDF

IEC TS 60079-48-2023 PDF

Explosive atmospheres-Part 48: Portable or Personal Electronic Equipment-Guide for the use of equipment without a certificate for use in Hazardous Areas

$50.44 $100.88 -50%
Product Code: IEC TS 60079-48
Stock In Stock
Edition: 1.0
Published: 11/2023
Number of Pages: 20
File Size: 1 file, 633 Bytes

Available Options

Product Description

Explosive atmospheres – Part 48: Portable or Personal Electronic Equipment – Guide for the use of equipment without a certificate for use in Hazardous Areas

Introduction: Suitable portable or personal equipment might not be commercially available with a certificate for use in hazardous areas, but might be needed for operational or health and safety reasons or could commonly be used as personal items. The acceptance of equipment without a certificate for use in hazardous areas would depend on the user organization policies and risk or needs assessment. This document is intended to assist users in understanding the potential for ignition from such equipment. This guidance could be further limited by regulations in some countries. This document addresses hazards relevant to portable and personal electronic equipment such as, spark ignition, hot surfaces, mechanically generated sparks, static electricity, radio frequency, ultrasonic energy, and optical radiation.

Scope: This part of IEC 60079, which is a Technical Specification, provides guidance for an owner or operator for the use of portable or personal electronic equipment to be used in hazardous areas requiring Equipment Protection Level (EPL) Gb, Gc, Db, or Dc that are not otherwise commercially available with a certificate. NOTE 1 This document is not intended to be used for certification purposes for equipment to be used in hazardous areas. NOTE 2 Examples of some of these types of equipment are provided in Annex A. NOTE 3 EPLs are derived from the hazardous area zones based on an additional risk assessment. The default relationship without a risk assessment in IEC 60079-14 is Zone 1 as EPL Gb, Zone 2 as EPL Gc, Zone 21 as EPL Db and Zone 22 as EPL Dc. This document does not apply to: equipment that is electrically connected to fixed equipment or fixed wiring during use in the hazardous area, for example a lead light connected to the premises wiring system by a plug and socket, portable or personal equipment with a certificate for use in a hazardous area, transportable equipment, portable or personal equipment used in Group I applications, battery powered tools, such as drills and saws, portable or personal equipment used in areas requiring EPL Ga or Da equipment, or, medical devices. NOTE 4 Devices which are implanted in the body are not exposed to atmosphere and are therefore not subject to hazardous area requirements, for example, pacemakers. The risk from other medical devices external to the body is beyond the scope of this document. This document does not address other considerations involving the use of portable or personal electronic equipment for other aspects of safety, for example, creation of a distraction from important work tasks, radio frequency interference with measurement and control equipment, or medical issues. This document supplements the guidance in IEC 60079-14 regarding the use of personal or portable equipment without a certificate for use in hazardous areas. NOTE 5 IEC 60079-14 requires that equipment with a certificate for hazardous areas should be used where possible and equipment without a certificate for hazardous areas should be subject t

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TS 60079-48-2023 PDF

IEC TS 60079-48-2023 PDF

$50.44 $100.88