Fire hazard testing – Part 2-21: Glowing/hot-wire based test methods – Fire containment test on finished units
Introduction: Fires might create hazards to life and property as a result of the generation of heat (emission of heat on fire hazard), and also as a result of the production of toxic effluent, corrosive effluent and smoke (fire effluents on the fire hazard). Fires start with ignition and then can grow, leading in some cases to flash-over and a fully developed fire. Resistance to ignition is therefore one of the most important parameters of a material to be considered in the assessment of a fire hazard. Most current fire hazard assessment techniques evaluate the resistance to ignition characteristics of a single material or component. These assessment techniques are able to drive the preselection and validation of materials and components but are not able to evaluate the possible interaction of materials or components in a complex environment such as in a finished unit, once a fire event is initiated. In a fault condition, a finished unit might be subject to the overheating of electrical connections and contacts. Such overheating can be caused by corrosion, poor crimp connections, incorrect assembly, erosion of contact surfaces, or mechanical fatigue. Insulating materials that are overheated can ignite and cause fire. It is difficult to simulate the actual conditions of potential faults in finished units; therefore all possible fire hazards should be taken into account at the design stage and subsequently during the preselection of materials and components. This fire containment test has be
Scope: This part of IEC 60695, which is a Technical Specification, specifies a fire containment test method for finished units. It is intended to verify the capability of containing of a fire event generated by an effective ignition source inside a finished unit. Unless otherwise specified by the relevant product standard, determination of the fire containment described in this document does not apply to any of the following: A single electrical component; A single electrical component when incorporated into a finished unit; Electrical installation products such as distribution boards, circuit protection devices, switchgear, controlgear, cable management system and electrical accessories (wiring devices). The test method described in this document does not apply to the following electrical connections: Low-power electrical connections contained in finished units, where the maximum power through the connection does not exceed 15 W. Soldered and welded electrical connections are exempted from the evaluations of this document. This document is intended to be used for evaluating the capability of fire containment of finished units, during the selection of finished units and in the design of finished units. The requirements, test method or test conditions of this document will not apply unless specifically referred to or included in the relevant publications.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 10 Evaluation of test results
- 11 Test report
- 12 Information to be given in the relevant product standard