Use of conventional touch voltage limits – Application guide Use of conventional touch voltage limits – Application guide
Introduction: This technical specification replaces the first edition of IEC/TR 61201 and provides voltage limits which are intended to be used by IEC technical committees as conventional touch voltage limits with regard to protection against electric shock. Its purpose is to facilitate harmonization and consistency among different IEC publications. The values proposed in this specification are derived from IEC/TS 60479-5. IEC 60479-5 gives the methodology used for the determination of touch voltage from the application of the Ohm’s law between different current thresholds corresponding to different physiological effects and body impedances corresponding to various current paths through the human body, contact areas, skin moisture at this contact area and on the type of current. Current thresholds and body impedances are provided by IEC/TS 60479-1. This specification discusses 50/60 Hz sinusoidal alternating voltage and pure direct voltage having no significant alternating component. Higher frequency alternating voltage is not included in this type of analysis as this would require a more complex body impedance model and would require the use of frequency factors for the current thresholds for the unwanted physiological effects. As this technical specification does not cover frequencies higher than 50/60 Hz, technical committees are requested to inform IEC/TC 64 about experience gained on this subject. Suggestions for modifications and additions to the technical specification should be sub
Scope: IEC/TS 61201, which is a technical specification, provides guidance on the use of conventional touch voltage limits with reference to thresholds given in IEC 60479-5. Consideration is given to different physiological effects, environmental conditions, contact conditions, etc. This specification only discusses voltages for sinusoidal a.c. at 50/60 Hz and pure d.c. having no significant a.c. component. This specification does not consider immersion of body parts or medical applications. Touch voltage limits are for use by technical committees as guidance for the determination of their own specific limits. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. It is not intended for use by manufacturers or certification bodies. One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.
Contents:
- FOREWORD
- INTRODUCTION
- Scope