IEC TS 61245-2015 PDF

IEC TS 61245-2015 PDF

Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems

$163.93 $327.86 -50%
Product Code: IEC TS 61245
Stock In Stock
Edition: 2.0
Published: 03/2015
Number of Pages: 40
File Size: 0 files

Available Options

Product Description

Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems

Introduction: The electrical strength of d.c. insulation under pollution conditions determines, in many cases, the dimensions and the design of the insulation. The d.c. test procedures as specified in this technical specification follow closely the ones established for a.c. by IEC 60507. This does not exclude the possibility that at a later time other d.c. test procedures will be defined. The main differences between this technical specification and IEC 60507 are: test circuit requirements include ripple factor, voltage drop and voltage overshoot. No requirements are made for the minimum short circuit current or ratio between short circuit and leakage currents; different criteria for the identification of flashover are given; for the salt fog test, a pre-conditioning process with d.c. voltage may be used by agreement; the wetting rate, rather than the steam injection rate, is prescribed; the measurement of the layer conductance is used to check the wetting action of the fog; as regards the solid layer methods, only the test procedure type "B" is considered due to the high scatter of the results obtained with tests carried out according to the type "A" procedure. The tests are deemed to be not a suitable measure to prove the insulation performance of polymeric or special types of insulators (e.g. insulators with semiconducting glaze or covered with any organic insulating material) under polluted conditions. The test procedures given in this standard do not take account of the different prop

Scope: This technical specification is applicable for the determination of the d.c. withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on d.c. systems with the highest voltage of the system greater than ± 1 000 V. These tests are not applicable to polymeric insulators, to greased insulators or to special types of insulators (e.g. insulators with semiconducting glaze or covered with any organic insulating material). The object of this technical specification is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. It may also be applied to hollow insulators with suitable precautions to avoid internal flashover. In applying these procedures to apparatus incorporating hollow insulators, the relevant technical committees should consider their effect on any internal equipment and the special precautions which may be necessary.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TS 61245-2015 PDF

IEC TS 61245-2015 PDF

$163.93 $327.86