Communication networks and systems for power utility automation - Part 80-6: Using IEC 61850 for communication between power system automation equipment and control or maintenance centres
Introduction: Following the publication of IEC 61850, substations using IEC 61850 technologies have been implemented. The concepts of IEC 61850 are also used in applications outside of the substation such as distributed energy resources, hydro power plants and wind power plants. Therefore, IEC 61850 forms the foundation for a globally standardized utility communication network. In the context of this technical specification IEDs in substations or those used in other, above- mentioned applications, will be referred to as 'power system automation equipment' (PSAE). The term 'power utility automation systems' is used for substation automation and other automation systems in the power utility domain. IEC 62357-1 describes the reference architecture for power systems management and associated information exchange. The communication between power system automation equipment and a control centre relate to the information exchange between the station and operation zone in the SGAM model. Beneath other classic telecontrol protocols IEC 62357-1 proposes the use of IEC 61850 for this purpose. IEC 61850 was initially prepared for information exchange between the devices of a substation automation system. The concepts are now also used in other power system application domains. The object models and configuration language introduced by IEC 61850 provide new possibilities for the management of the automation system. A direct and seamless access from the control and maintenance centres to the IEDs of the
Scope: 1.1 General This part of IEC 61850, which is a technical specification, provides a comprehensive overview of the various aspects that need to be considered while using IEC 61850 for information exchange between power system automation equipment and control or maintenance centres or other system level applications. This document: defines use cases and communication requirements that require an information exchange between power system automation equipment and control or maintenance centres; describes the usage of the configuration language of IEC 61850-6; gives guidelines for the selection of communication services and architectures compatible with IEC 61850; describes the engineering workflow; introduces the use of a Proxy/Gateway concept; describes the links regarding the Specific Communication Service Mapping (SCSM); defines the abstract conformance test cases that build the basis for the conformance test procedures elaborated by the UCAIug Testing Sub Committee. This document does not define constraints or limitations for specific device implementations. There is no specific clause for cyber security, which is tackled when it is necessary. The model for IEC TS 61850-80-6 provides security functions based upon the security threats and security functions found in IEC TS 62351-1 and IEC TS 62351-2. This document touches on several security aspects with the following basic assumptions: Information authentication and integrity (e.g., the ability to provide tamper detection) is needed. In case of operational issues, encryption (to achieve confidentiality) is optional. This typically applies for GOOSE and SV messages in the power utility automation system LAN. End-to-end information authentication and integrity methods, regardless of information hierarchies, need to be provided. The typical method to provide this security function is through some type of information/message authentication code. IEC 62351-4 and IEC 62351-9 describe how authentication and integrity is achieved for IEC 61850-8-1. IEC 62351-4 provides means to ensure end-to-end data integrity through Proxy/Gateways. Beneath information authentication and integrity, information availability is an importa
Contents:
- FOREWORD
- INTRODUCTION
- Scope