Application integration at electric utilities – System interfaces for distribution management – Part 2: Glossary
Introduction: The IEC 61968 series is intended to facilitate inter-application integration, as opposed to intra-application integration, of the various distributed software application systems supporting the management of utility electrical distribution networks. Intra-application integration is aimed at programs in the same application system, usually communicating with each other using middleware that is embedded in their underlying runtime environment, and tends to be optimized for close, real-time, synchronous connections and interactive request/reply or conversation communication models. IEC 61968, by contrast, is intended to support the inter- application integration of a utility enterprise that needs to connect disparate applications that are already built or new (legacy or purchased applications), each supported by dissimilar runtime environments. Therefore, IEC 61968 is relevant to loosely coupled applications with more heterogeneity in languages, operating systems, protocols and management tools. IEC 61968 is intended to support applications that need to exchange data on an event driven basis. IEC 61968 is intended to be implemented with middleware services that broker messages among applications, and will complement, but not replace utility data warehouses, database gateways, and operational stores. The series of standards will be using a lot of definitions, terms and abbreviations from the area of distribution management as well as from the area of Information and Communication
Scope: This part of IEC 61968 identifies and explains terms and abbreviations used in the remaining parts of IEC 61968. This glossary, accompanying the IEC 61968 series, is the second part in the series that, taken as a whole, defines interfaces for the major elements of an interface architecture for distribution management systems (DMS). As used in IEC 61968, a DMS consists of various distributed application components for the utility to manage electrical distribution networks. These capabilities include monitoring and control of equipment for power delivery, management processes to ensure system reliability, voltage management, demand-side management, outage management, work management, automated mapping and facilities management. Terms and definitions For the purposes of the IEC 61968 series, the following terms and definitions apply. 2.1 abstract component smallest logical block of software considered in the IEC 61968 interface reference model NOTE Abstract components have interfaces that will be defined in parts 3 to 10 of the IEC 61968 series. It is expected that different vendors will supply physical application components that support the interfaces for one or more abstract components. 2.2 absolute data data which is based on a fixed sample at a prescribed moment in time NOTE 1 The data may have been scaled and may consist of a signed value (as opposed to unsigned). [Aclara 2008] NOTE 2 See also: "incremental data". 2.3 account number unique number issued by a customer information system to identify a specific customer account within a given utility [Aclara 2008] 2.4 accuracy (of a measurement) quality of freedom from mistake or error, that is, of conformity to truth or to a rule NOTE 1 Accuracy is distinguished from precision as in the following example: A six-place table is more precise than a four-place table. However, if there are errors in the six-place table, it may be more or less accurate than the four-place table.
Contents:
- FOREWORD
- INTRODUCTION
- Scope