High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 2: Harmonic performance aspects
Introduction: IEC 62001 (all parts) deals with the specification and design evaluation of AC side harmonic performance and AC side filters for HVDC schemes. It is intended to be primarily for the use of the utilities and consultants who are responsible for issuing the specifications for new HVDC projects and evaluating designs proposed by prospective suppliers. Harmonic performance is discussed in several places throughout the various parts of the IEC 62001 series and is also the topic of the IEC 61000 series. The IEC 62001 series is structured in five parts as follows. IEC TR 62001-1 – Overview This part concerns specifications of AC filters for high-voltage direct current (HVDC) systems with line-commutated converters, permissible distortion limits, harmonic generation, filter arrangements, filter performance calculation, filter switching and reactive power management and customer specified parameters and requirements. IEC TS 62001-2 – Harmonic performance aspects This part deals with telephone interference, current-based interference criteria, field measurements and compliance verification. IEC TS 62001-3 – Modelling aspects This part addresses modelling of three specific aspects of design: AC network impedance modelling, the treatment of pre-existing harmonics in performance and rating calculations, and harmonic interaction across converters (cross-modulation). IEC TR 62001-4 – Equipment This part concerns steady-state and transient ratings of AC filters and their components, power los
Scope: This part of IEC 62001 gives a guidance to the specification and design evaluation of AC filters of high-voltage direct current HVDC) systems, specifically on harmonic performance aspects. This document focusses on three specific areas of interest. Clause 4 discusses telephone interference related to the operation of HVDC transmission, including the derivation of appropriate harmonic limits. Clause 5 deals with all aspects of current-based harmonic performance criteria and their application. Clause 6 is concerned with field measurement and verification of compliance with specified harmonic limits. This document concentrates on passive AC filter technology and line-commutated high-voltage direct current (HVDC) converters, but much of the content is equally relevant to VSC converter technology. Where there is a distinction, this is indicated in the text. The scope of this document covers AC side filtering for the frequency range of interest in terms of harmonic distortion and audible frequency disturbances. It excludes filters specifically designed to be effective in the PLC and radio interference spectra.
Contents:
- FOREWORD
- INTRODUCTION
- Scope