Recommendations for small renewable energy and hybrid systems for rural electrification – Part 7-1: Generators – Photovoltaic generators
Introduction: The IEC 62257 series of publications intends to provide to different players involved in rural electrification projects (such as project implementers, project contractors, project supervisors, installers, etc.) documents for the setting-up of renewable energy and hybrid systems with a.c. voltage below 500 V, d.c. voltage below 750 V and power below 100 kVA. These publications provide recommendations for choosing the right system for the right place; designing the system; operating and maintaining the system. These publications are focused only on rural electrification concentrated in, but not specific to, developing countries. They must not be considered as all-inclusive of rural electrification. The publications try to promote the use of renewable energies in rural electrification. They do not deal with clean mechanism developments at this time (CO2 emission, carbon credit, etc.). Further developments in this field could be introduced in future steps. This consistent set of publications is best considered as a whole, with different parts corresponding to items for the safety and sustainability of systems at the lowest possible life- cycle cost. One of the main objectives of the series is to provide the minimum sufficient requirements relevant to the field of application, i.e. for small renewable energy and hybrid off-grid systems. The purpose of IEC 62257-7-1 is to propose a technical specification for the design and building of small PV generators (e.g. up to 100 kWp) used
Scope: This part of IEC 62257 specifies the general requirements for the design and safety of generators used in decentralized rural electrification systems. The earthing systems of the exposed conductive parts and neutral earthing systems which are considered in this technical specification are those specified in IEC 62257 series for IES (see IEC 62257-9-3 and IEC 62257-9-4) and CES (IEC 62257-9-2). This technical specification contains requirements for ELV and LV PV arrays (see Table 1). Particular attention must be paid to voltage level, as this is important for safety reasons and has an influence on protective measures and on the skill and ability level of people operating the systems. Table 1 – Voltage domains for PV arrays Voltage domain Voltage Alternating current Smoothed direct current ELV Un ≤ 50 V Uoc ≤ 120 V 50 V < Un ≤ 1 000 V 120 V < Uoc ≤ 1 500 V NOTE ELV limits are provided by IEC 61201. For the sake of completeness, this technical specification gives requirements for d.c. voltages below and above 120 V. The aim is to provide safety and fire protection requirements for: uninformed persons, including owner(s)/occupier(s) and users of the premises where photovoltaic arrays are installed; informed workers (e.g. electricians) working on these systems; and emergency workers (for example fire fighters). For installation of PV arrays see IEC 60364-7-712.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 4.1.10 Component voltage ratings
- 4.1.11 Performance issues