Nanomanufacturing – Key control characteristics – Part 9-1: Traceable spatially resolved nano-scale stray magnetic field measurements – Magnetic force microscopy

Introduction: Measurements of magnetic fields that are homogeneous over macroscopic volumes can be made traceable to the SI standards, and traceable calibration chains from the national metrology institutes to the end users are well-established. However, many important industrial applications such as magneto-resistive position, angle, or motion control rely on precision sensing of spatially varying magnetic fields. Such spatially varying magnetic fields can, for example, be generated by a magnetic bit pattern of a magnetic encoder scale. Today, magnetic encoder bit patterns have typically a lateral periodicity above 100 μm. Based on stray field interpolation, such encoders are applied, for example, for precision positioning systems with sub-micrometre resolution. However, such precision positioning requires reliable local field measurements which are not yet underpinned by any suitable standards. Today, local magnetic stray field measurements with resolutions from above 50 µm down to below 500 nm can be realized by scanning magnetic field detection (SMF) methods with different field sensors such as Hall sensors, magneto-resistive (MR) sensors and magnetically coated tips on an oscillating cantilever (magnetic force microscopy (MFM)), or with imaging techniques like Kerr and magneto-optical indicator film (MOIF) microscopy. Achievable spatial resolution and typical scanning area are compared in Figure 1. MFM provides a significantly higher resolution than other SMF techniques and MOIF (see

Scope: This part of IEC 62607 establishes a standardized method to characterize spatially varying magnetic fields with a spatial resolution down to 10 nm for flat magnetic specimens by magnetic force microscopy (MFM). MFM primarily detects the stray field component perpendicular to the sample surface. The resolution is achieved by the calibration of the MFM tip using magnetically nanostructured reference materials. The objective of this document is to define and describe: reference materials for traceable high resolution magnetic stray field measurements; the calibration procedures to determine the instrument calibration function (ICF) and, if required, MFM key parameters entering the deconvolution process; the deconvolution process which allows to calculate quantitative stray field data from the measured MFM data using the ICF; the evaluation of the measurement uncertainty, including the prevention of potential artefacts which can occur during the measurement leading to a misinterpretation of the results.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC TS 62607-9-1-2021 PDF

IEC TS 62607-9-1-2021 PDF

$239.59 $479.18