IEC TS 62743-2012 PDF

IEC TS 62743-2012 PDF

Radiation protection instrumentation-Electronic counting dosemeters for pulsed fields of ionizing radiation

$100.88 $201.76 -50%
Product Code: IEC TS 62743
Stock In Stock
Edition: 1.0
Published: 09/2012
Number of Pages: 30
File Size: 1 file, 279 Bytes

Available Options

Product Description

Radiation protection instrumentation – Electronic counting dosemeters for pulsed fields of ionizing radiation

Introduction: The specification and determination of the special characteristics required for dosemeters to be used in pulsed fields of ionizing radiation have been excluded from all standards for direct reading personal and environmental dosemeters issued before 2012 for radiation protection purposes. These standards only specify characteristics for continuous radiation. This Techni- cal Specification provides the necessary information for the measurement of one single radia- tion pulse, which is the most difficult situation to be measured. The characteristics of a dose- meter for repeated pulses is expected to be better than for one single radiation pulse with the same parameters but worse than for continuous radiation, i.e., in between of the characteris- tics for these two extreme conditions. This Technical Specification applies for such direct reading dosemeters that use pulse counting for the determination of the measured dose value. Dosemeters that use delayed pulses, e.g., due to activation by neutrons, are excluded. The concept is similar to the concept used for other influence quantities, e.g., radiation energy. The workplace is characterized by the parameter range occurring at that workplace, i.e., in the case of energy the expected possible values of radiation energy. It can then be determined if the dosemeter under consideration can be used. The required parameters for a workplace where pulsed radiation occurs are the minimum value of the radiation pulse duration, tpulse, min,

Scope: This Technical Specification applies to all types of counting dosemeters, irrespective of the measuring quantity and the type of radiation intended to be measured. It ensures that a single radiation pulse can be correctly measured even if the dosemeter is in the internal state relevant for measuring background or environmental radiation. The characteristics of the dosemeter for repeated pulses is expected to be better than for one single radiation pulse with the same parameters but worse than for continuous radiation, i.e., in between of the characteristics for these two extreme conditions. This Technical Specification does not specify the characteristics of the dosemeter for repeated pulses. The Technical Specification does not apply for those types of counting dosemeters that either do not have an indication or software read-out of the dose rate and the number of pulses counted, convert the non-pulsed detector signal to counts by a converter, or use nuclear reactions to generate long and nearly continuous secondary radiation fields which then are measured by the dosemeter using counting techniques instead of measuring the direct radiation pulse. The pulsed radiation source is characterized by the parameters radiation pulse duration, tpulse, pulse peak dose rate, peak pulse, H dose per radiation pulse, Hpulse. This Technical Specification considers the pulsation of the radiation field as an additional influence quantity like particle energy and direction of radiation incidence. Therefore, the tests described are additional to all the tests in the respective standards. This technical specification describes methods to determine the characteristic parameters of the counting dosemeter. A prerequisite of the method is that the model function of the dose- meter can sufficiently be approximated by dead count count dose (1) where Gdose is the dose indication of the dosemeter, Gcount is the dose indication per counting event, ncount is the number of counting events counted by the dosemeter, and kdead is the correction for dead time losses. This simplified model function should not fully describe the dosemeter but it should be valid only – maybe with effective values –

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope