General requirements for residual current operated protective devices for DC systems
Introduction: In AC systems, residual current devices are used to provide protection against the risk of electric shocks. In IEC 60364 (all parts), residual current devices are used for automatic disconnection of supply in case of fault (see Clause 411 of IEC 60364-4-41:2005) and residual current devices with rated residual operating current not exceeding 30 mA are used as additional protection (see 415 of IEC 60364-4-41:2005). IEC SC 23E has developed a set of standards for residual current operated protective devices intended to be used in AC systems. DC systems are used for applications such as photovoltaic installations, data centres and telecom centres, and electric vehicle charging systems. In addition, standards for plugs and socket-outlets for ICT equipment installed in date centres and telecom centre have been published. Therefore, a reference document for residual current devices intended to be used in DC supply systems is necessary. Residual current devices for DC systems may be used to provide fault protection (automatic disconnection of supply according to Clause 411 of IEC 60364-4-41:2005); they may also be used to provide protection against direct contact. They provide protection against electric shock downstream of the device in DC networks. This document defines the operating characteristics for residual current operated protective devices for DC systems. Details of how they should be installed to provide the desired level of protection are specified in the various parts o
Scope: This document provides general minimum requirements, recommendations and information for the drafting and testing procedures of standards for residual current operated protective devices, intended to be used in DC systems having a rated voltage not exceeding 400 V DC and a rated current not exceeding 125 A, hereafter referred to as DC-RCDs. NOTE 1 This document can also be used as a guide for DC-RCDs with voltages up to 1 500 V DC. This document is primarily intended to be used as a reference for drafting product safety standard for DC-RCDs. This document cannot be used alone but is intended for use by technical committees in the preparation of standards for products similar to those mentioned in the scope of this standard. This document applies to a device which detects a residual current, compares it to a reference value, and opens the contacts or poles when the residual current exceeds this reference value. Any association of devices, each one of them performing separately one or two of the above-mentioned functions, but acting together in order to accomplish all three functions, is also covered by this document. NOTE 2 RCMs (residual current monitor according to IEC 62020) whose purpose is to monitor an electrical installation and not to provide protection are not covered by this document and cannot be considered similar or equivalent to DC-RCDs. DC-RCDs are intended to provide fault protection, the exposed conductive parts of the installation being connected to an appropriate earth electrode, in accordance with IEC 60364-4-41. DC-RCDs having a rated residual operating direct current not exceeding 80 mA are also used as a provision for additional protection in case of failure of the protective means against electric shock. In accordance with IEC 60364-4-42, residual current devices with a rated residual operating current not exceeding 300 mA can also be used to provide protection against fire hazards due to a persistent earth fault current. DC-RCDs are suitable for isolation. They are suitable for all supply systems, with the exception of single-pole DC-RCDs with two current paths which are not suitable for use in IT systems. DC-RCDs of the general type are
Contents:
- FOREWORD
- INTRODUCTION
- Scope