IEC TS 63070-2019 PDF

IEC TS 63070-2019 PDF

Ultrasonics - Field characterization - Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air

$132.41 $264.81 -50%
Product Code: IEC TS 63070
Stock In Stock
Edition: 1.0
Published: 02/2019
Number of Pages: 30
File Size: 1 file, 1 Byte

Available Options

Product Description

Ultrasonics - Field characterization - Infrared imaging techniques for determining temperature elevation in tissue-mimicking material and at the radiation surface of a transducer in still air

Introduction: This Technical Specification describes primarily how to measure temperature elevation generated by an ultrasound transducer by using an infrared (IR) camera system aimed at insonified tissue-mimicking material located in still air. Split TMM (tissue-mimicking material) is configured as a phantom to observe temperature elevation and distribution for assessing fields generated by diagnostic ultrasound equipment and by physiotherapy and high intensity therapeutic ultrasound (HITU) equipment. Temperature measurement of the radiating surface of an ultrasound transducer under the still- air condition is also considered for the evaluation of extensive temperature distributions as required in IEC 60601-2-37:2007 and IEC 60601-2-37:2007/AMD1:2015.

Scope: This document is applicable to ultrasonic equipment designed for the medical field of application. It covers both diagnostic and therapeutic (physiotherapy and HITU) equipment. This document describes transducer evaluation by the infrared imaging technique using a split TMM-phantom for qualitative and quantitative estimation of temperature distributions in tissue-mimicking material, resulting from absorption of ultrasound and from heating of the transducer itself. This document also describes a method to measure transducer-surface temperature, while the transducer is driven under the still-air condition. NOTE 1 When the transducer is in contact with tissue-mimicking material, the heating of the transducer itself depends on the actual efficiency of the transducer, on the specific conditions for thermal transfer to or from the tissue-mimicking material, and on the transmitting/receiving electronic circuits, such as a switching circuit or pre- amplifier in some cases. NOTE 2 The test objects specified in this document are for the measurement of temperature rise and not for the determination of thermal index, which is, by definition in IEC 62359:2010 and IEC 62359:2010/AMD1:2017, an algebraic combination of acoustical field quantities and therefore is not a physically measurable quantity.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope