Reliability of industrial automation devices and systems – Part 1: Assurance of automation devices reliability data and specification of their source
Introduction: Reliability data of automation devices is often used by assessors and system integrators to predict the properties of a complete system. The assessors and system integrators need to know how this data was acquired. This specification gives guidance to device manufacturers on how to present the reliability data of their devices and how to indicate the source of the reliability data in a manner that assessors and system integrators can make best use of. This includes the specification of reference conditions. Three methods of data acquisition are distinguished: 1) Calculation. This is the preferred method for electronic devices. 2) Observation of devices in the field. This is the preferred method if no relevant data is available to make a forecast by calculation. 3) Laboratory tests. This is the preferred method for mechanical and electromechanical devices. Laboratory durability tests are, however, not deemed to be suitable if said devices will operate in the low demand mode (in the sense of IEC 61508-4:2010, 3.5.16). NOTE Burn-in and break-in are not considered in this specification and will be addressed in future documents. This specification is the first part of the series. This part of IEC 63164 concentrates on reliability data, including assurance of reliability data and methods of field reliability data collection. How to get data from calculation and laboratory tests is described in other documents. Therefore, this part will concentrate on random hardware failures, but i
Scope: This part of IEC 63164 provides guidance on the assurance of reliability data of automation devices. If the source of this data is calculation, guidance is given on how to specify the methods used for this calculation. If the source is from observation of devices in the field, guidance is given on how to describe these observations and their evaluations. If the source is the outcome of laboratory tests, guidance is given on how to specify these tests and the conditions under which they have been carried out. This document defines the form to present the data. The components considered in this document are assumed not to need any break-in phase before full range usage. When devices are used for functional safety application, the requirements of IEC 61508 (all parts) and related standards are considered.
Contents:
- FOREWORD
- INTRODUCTION
- Scope