Representation of communication in power utility automation
Introduction: The data communication system is a critical point in the real time operation of a power utility automation system. Information from the system is retrieved and used for reliable operation, for supervision, and for efficient maintenance work in power utility automation systems, such as hydro power plant, thermal power plant, transmission station, distribution station, industrial site, etc.; hereby referred to as substations. Power utility automation systems, including those for substations, have been increasingly modernized thanks to their benefits to power utilities. Digital data exchange, based on IEC 61850 (all parts), among the functions in the system, replaces the copper hardwired conventional communication. The exchange of digital information, in the form of data objects and data attributes, between intelligent electronic devices (IEDs), has become very common in utility automation and these data are essential for control and protection of the power grid, and the amount of such data exchanges is increasing. The engineering tools available for configuration of the communication systems are typically focusing on the data exchange between tools and less on readability for human perception. Documents prepared by these tools are often comprehensive and well-structured files, for example, in XML-format, but are difficult to read and to understand and could therefore be inappropriate in some steps of the product/system life cycle. With the increasing amount of data exchanges an
Scope: This document specifies a structure for representation of exchanged information that is essential for testing and maintenance of the devices in power utility automation systems. It is mainly intended to be applied to communication equipment that communicate information in accordance with IEC 61850 (all parts) in at least one part of their communication flow. The following communication equipment is included within the scope: optical instrument transformer; conventional instrument transformers related to IEC 61850 traffic; merging unit; stand-alone merging unit; protection, control and measuring devices with at least one IEC 61850 interface; switchgear control unit (breaker IED); switchgear providing IEC 61850 interface; IEC 61850 time synchronization device; IEC 61850 gateway (RTU) and station HMI; digital disturbance recorder / digital fault recorder; digital communication protocol gateways with at least one IEC 61850 interface; protection, control and measuring devices that utilise a proprietary protocol for communication with devices that have at least one IEC 61850 interface. The following communication equipment, scheme and protocols are excluded from the scope: IEC 61850 Ethernet switches and network topology; PMU phasor measurement unit with at least one IEC 61850 interface; the full path of substation-to-substation communication; EXAMPLE 1: The description of RGOOSE Publisher in substation A does not include the description of R-GOOSE Subscriber in substation B. functions with only hardwired communication, e.g. direct analogue copper wired connection; EXAMPLE 2: A current transformer connected to a protection relay with hardwired tripping of a circuit breaker. functions using only proprietary communication protocol systems; EXAMPLE 3: A dedicated system for collecting disturbance recorder files with courier protocol or path from IEC 608705103 to IEC 60870-5-101 will not be presented in this document. protocol mappings to XMPP (IEC 61850-8-2). This document forms a supplement to other documentation standards in power utility automation. It also harmonizes the representation of the logical data flow structures based on IEC 61850 communication among differe
Contents:
- FOREWORD
- INTRODUCTION
- Scope